HomeMy WebLinkAboutCorrespondence re: Plan Review 2009 irk ONTVILLE TEL(860)848-1175TOWN OF M Raymond T.Occhialini Fire Marshal Fire Marshal's Office FAX(860)848-4063 310 Norwich-New London Tpke. Uncasville,CT 06382 April 28, 2009 Mr. Vernon Vesey II Building Official 310 Norwich New London Turnpike Uncasville, Connecticut 06382 RE: Plan Review 36/46 Platoz Drive Uncasville, Dear Vern, The Town of Montville Fire Marshal reviewed plans submitted to complete the two eight(8) family dwelling units located at 36 and 46 Platoz Drive. In accordance with the code modification approved by the State Fire Marshal sprinklers are not required but the rest of the R- 2 occupancy must meet all of the requirements of the 2005 Connecticut Fire Safety Code. We will need the following information or details to complete the code review. 1. CFSC 2005 section 1010 ramps, provide details on the ramp so compliance can be determined. 2. CFSC 2005 section 1012 guards, provide details on the guards on the deck. 3. CFSC 2005 section 1009 stairs, the stairs do not meet the requirements of the fire code, submit stair details. 4. CFSC 2005 section 1009 handrails, no handrail details were provided. 5. CFSC 2005 section 701.1, references the Connecticut State Building Code for fire separations. Provide details on the rated fire separations such as UL or FM. Until we get the requested information code compliance cannot be determined. If you should have any questions please contact me at the Montville Fire Marshal's Office. Sincerelya 'aymond T. Occhialini Fire Marshal cc: John Mandes file Town of Montville 0 ,.r 310 Norwich-New London Tpke. Uncasville, Ct. 06382 5/11/09 John Mandes 11 Devonshire Dr. Waterford, Ct. 06385 Your applications, dated 4/21/09 for construction of 8 unit apartment buildings at 36 and 46 Platoz Dr. in Uncasville, Ct., are being rejected. I am unable to complete the review with the plans submitted. Please furnish the amended or missing information requested. The plans are incomplete and/or information furnished is not code compliant, as follows: Building & Structural- IBC 1. IBC 106.1.1 Applicable Code(s), Use Group, Type Construction not indicated 2. IBC 106.1.3 Exterior wall envelope compliance 3. IBC 1603.1.5 Earthquake load design data required NN4. IBC 1607.7.1 Handrail & Guardrail Load design data required 5. IBC 1601.1.1 Method or Standard used to determine wind loads not indicated on plans 0 IBC 1107.6.2.1 IBC 1107.6.2.1.1 IBC 1107.6.2.1.2 IBC 1107.7.1.1 All units on the grade floor level are required to be either type A or Type B accessible units. Only one unit is indicated as accessible and the data furnished is incomplete. "7. IBC 907.2.10.1.2 Smoke detectors not properly located IBC 1006.1 Means of egress illumination not indicated on plans IBC 1006.3 Emergency power for means of egress illumination not indicated on plans `tet 10. IBC 1009.5.2 Exterior stairs required to be protected from accumulation of snow or ice ® IBC 1009 Handrail & Guardrail and Stair data insufficient to determine code compliance 419 IBC 1010 Ramp data insufficient to determine code compliance 1y 13. IBC 1203.2 Attic ventilation required 114. IBC 1209.2 Attic access required 15 IBC 1209.3 Show location of and access to mechanical equipment and electrical equipment -N16. IBC 2304.11 Protection from decay and termites shall be provided by use of naturally durable or Preservative-treated wood 17. IBC 711.3 Floor assemblies separating R-2 dwelling units required to be 1-hour fire resistance rated construction. IBC 702 -Definition of Fire-Resistant Rating-"The period of time a building element, component or assembly maintains the ability to confine a fire, as determined by tests, or the methods based on tests, prescribed in section 703" Furnish data as to how this fire resistance rating was determined isi ti, r: IBC 711.4 Supporting construction shall be protected to afford the required fire-resistance ,. rating of the horizontal assembly supported. N\ '15. IBC 708.3 Fire Partitions separating R-2 dwelling units are required to be 1-hour fire resistance `" rated construction. IBC 702 -Definition of Fire-Resistant Rating—"The period of time a building element, component or assembly maintains the ability to confine a fire,...as determined by tests, or the methods based on tests, prescribed in section 703" Furnish data indicating fire resistance rating and test or used 0 IBC 708.4 Fire partitions shall be continuous—Plans do not show details for intersection of fire partitions and floor/ceiling assemblies or details for intersection of fire partition and interior and exterior partitions. 11 \+1 IBC 713.3.1 Furnish locations& data for fire-resistance rated wall penetrations 1 18. IBC 803 Plans do not indicate interior wall and ceiling finishes to be used and their er classification. 19 IBC 804 Plans do not indicate interior floor finishes or their classification V 20. IBC 1802.2.3 A subsurface soil investigation is required to determine ground water table, unless \ the foundation wall is waterproofed in accordance with 1807. r��5 21 IBC 1805.5.6 Foundation drainage required installed in accordance with 1807.4.2 and1807.4.3 unless the foundation is designed to support the full hydrostatic pressure of un-drained backfill "---'22. IBC 1207.1 Furnish sound transmission data 23. Furnish basement floor plan Electrical—NEC 0 NEC 230 Additional data required for electrical service: A. Disconnecting means B. Size of disconnect(s)—Load calculations C. Individual or grouped meters/disconnects D. Location of service E. Location of service panels 2 See# 10 Above Exterior Egress Lighting& emergency power data required 3 NEC 210.12 Identify Arc Fault protected outlets NEC 210.8 Identify GFCI protected outlets 5 NEC 210-52(E) Outdoor outlets required for grade level units Plumbing—IPC 1) IPC 106.3.1 Furnish riser diagram 0 WPCA Furnish data for house trap location, size, venting and cleanouts 0 Hot water? a See# 17 above Fire separation penetrations f) IPC 314.2.1 Furnish details for condensate disposal (2nd floor A/C units) 0 IPC 405.3.1 Plans not to scale, furnish scale drawing for typical bathroom fixture location 0 IPC 424.3 Furnish data for shower valves { 0 IPC 604 Furnish design calculations to determine compliance with sections 604.3, 604.4, 604.5, 604.6, 604.7 9 IPC 608 Furnish backflow prevention data as appropriate 0 IPC 702 Sewer, drain and vent pipe required to meet requirements of section 702 1 Other Requirements Other Department Approvals Sign Off Sheet: Fire Marshal approval Planning&Zoning approval WPCA approval Public Works approval Fee Due- $4424.89 per building Vernon D. Vesey II Building Official Smith Engineering 128 Jupiter Point Road Groton, CT 06340 (860)446-1636 June 1, 2009 Town of Montville 310 Norwich-New London Turnpike Uncasville, CT 06382 Attention: Mr. Vernon D. Vasey II -Building Official Subject: Apartment Buildings - 36 &46 Platoz Drive-Uncasville, CT 06382 Reference: Your Letter to Mr. John Mandes dated May 11, 2009 , Same Subject Gentlemen: Acting as an agent for Mr. Mandes I am forwarding the information requested in reference letter on subject buildings for the Building& Structural - IBC Section. The Electrical&Plumbing Sections will be addressed by others. Itemization numbers of information provided agree with your numbers used in the reference document. Building& Structural - IBC 1. IBC 106.1.1 - Information submitted in General Notes Item#1 on Drawing Al. 2. IBC 106.1.3 - Information shown in Detail#8 on Drawing S2. 3. IBC 1603.1.5 - Information submitted in General Notes Item#2 on Drawing Al. 4. IBC 1607.7.1 -Handrail & Guardrail Load Design Data submitted in General Notes Item#3 on Drawing Al. 5. IBC 1609.1.1 -Wind information included in General Notes#4 on Drawing Al. 6. IBC 1107.7.1.1, etc. - Changes have been made to Drawing Al so that all Type "A" & "B" units on the lower floor of both buildings are accessible. 7. IBC 907.2.19.1.2 - Smoke Alarms have been added to Drawings Al & A2 - 2/unit. 8. IBC 1006.1 -Under"Exceptions Item 3" for Group R-2 means of egress illumination is not required. 9. IBC 1006.3 - Since illumination is not required emergency power should not be required. 10. IBC 1009.5.2 -Roof structure added over stairways in Drawing A3. 11. IBC 1009 -Handrail, Guardrail& Stair data added to Drawing A3. 12. IBC 1010 -Ramp data has been added to Drawing A3 & Al. 1. Smith Engineering 13. IBC 1203.2 - Soffit& ridge ventilation added to Section A-A on Drawing S2. 14. IBC 1209.2 - Attic folding stairs added to Drawing A2. 15. IBC 1209.3 -Information to be provided by Electrical& Mechanical providers. 16. IBC 2304.11 - Detail#9 on Drawing S2 shows PT lumber being used. 17. IBC 711.3, 708.3 &708.4 -Information on floor/ceiling and wall fire assemblies is shown on Drawings S2 & A3 in Details#6& 7 and Sections A-A, B-B & C-C. 18. IBC 711.4& 713.3.1 - There are no openings or penetrations in the fire partitions. 19. IBC 803 & 840 -Room finish schedule has been included on Drawing A2. 20. IBC 1802.2.3 - In the Spring of 2006 during repair and replacement of portions of the existing foundation wall a subsurface soil inspection was performed. There was no visual evidence of a past or present existence of a water table in the excavations performed requiring waterproofing. 21. IBC 1805.5.6 - The foundation wall has reinforcement and should withstand full height hydrostatic pressure. 22. IBC 1207.1 - Sound transmission data of the floor/ceiling assembly between the first and second floor on Drawing A3 in Detail#7. 23. Basement floor plans and crawl space are shown on Drawing 51. If you have any further questions or I can be of further assistance please contact me. Thank you. Respectfully yours, 4,/ VIP t_ ' obert S. Smith, P.E. Smith Engineering cc: Mr. John Mandes 2. r► 1 Town of Montville 310 Norwich-New London Tpke. Uncasville, Ct. 06382 6/30/09 John Mandes 11 Devonshire Dr. Waterford, Ct. 06385 Re 36 & 46 Platoz Dr., Uncasville On 5/11/09 I sent you a rejection of your applications dated 4/21/09. On 6/19/09 you delivered amended plans and additional information regarding your application. I have reviewed the changes and additional information. Your amended applications are being rejected as follows: Please note: My first rejection notice was improperly numbered and I have corrected the numbering. Items highlighted are still missing information or otherwise not code compliant. Requests for additional information or changes are in bold print. Building & Structural - IBC 1. IBC 106.1.1 Applicable Code(s), Use Group, Type Construction not indicated 2. IBC 106.1.3 Exterior wall envelope compliance 3. IBC 1603.1.5 Earthquake load design data required 4. IBC 1607.7.1 Handrail & Guardrail Load design data required 5. IBC 1601.1.1 Method or Standard used to determine wind loads not indicated on plans 6. IBC 1107.6.2.1 IBC 1107.6.2.1.1 IBC 1107.6.2.1.2 IBC 1107.7.1.1 All units on the grade floor level are required to be either type A or Type B accessible units. Only one unit is indicated as accessible and the data furnished is incomplete. 1107.2 Type A & B units shall comply with the applicable portions of chapter 10 of the 2003 ICC/ANSI IBC 1107.3 Type A and B units shall be accessible including toilet and bathing rooms, kitchen, living and dining areas, and any exterior spaces. Furnish details with dimensions and other data for all accessible fixtures, features and spaces for both Type A and Type B units. 7. IBC 907.2.10.1.2 Smoke detectors not properly located 2 8. IBC 1006.1 Means of egress illumination not indicated on plans 9. IBC 1006.3 Emergency power for means of egress illumination not indicated on plans The information furnished by your engineer indicates that means of egress lighting is not required per IBC 1006.1 exception #3. Exception #3 addresses areas WITHIN the dwelling units. Means of Egress lighting is required, including the exit discharge. Indicate means of egress lighting on plans. Indicate emergency power for means of egress lighting. 10. IBC 1009.5.2 Exterior stairs required to be protected from accumulation of snow or ice 11. IBC 1009 Handrail & Guardrail and Stair data insufficient to determine code compliance IBC 1012.1 Guardrail height required to be 42"-Plans indicate 34" for both guardrails and handrails 12. IBC 1010 Ramp data insufficient to determine code compliance IBC 1010.10 Per IBC 1012.1 Guardrail height required to be 42"-Plans indicate 34" for both guardrails and handrails IBC 1010.7.1 Furnish data for slip-resistant material on ramp surface IBC 1010.7.2 Ramps are required to be protected from accumulation of snow or ice. Indicate how you plan to accomplish this. ICC/ANSI 405.6 Indicate total rise for ramps 13. IBC 1203.2 Attic ventilation required 14. IBC 1209.2 Attic access required 15. IBC 1209.3 Show location of and access to mechanical equipment and electrical equipment Data not furnished- Furnish data 16. IBC 2304.11 Protection from decay and termites shall be provided by use of naturally durable or Preservative-treated wood 17. IBC 711.3 Floor assemblies separating R-2 dwelling units required to be 1-hour fire resistance rated construction. IBC 702 - Definition of Fire-Resistant Rating-"The period of time a building element, component or assembly maintains the ability to confine a fire, as determined by tests, or the methods based on tests, prescribed in section 703" Furnish data as to how this fire resistance rating was determined 18. IBC 711.4 Supporting construction shall be protected to afford the required fire-resistance rating of the horizontal assembly supported. Item not addressed - Section 711.4 referenced in #17 of engineer's response, where he states "There are no penetrations in the fire partitions." Section 711.4 deals with continuity of horizontal assemblies and protection of their supporting structure.711.5 & 712 deal with penetrations in horizontal assemblies. Furnish details for penetrations thru horizontal assemblies. 19. IBC 708.3 Fire Partitions separating R-2 dwelling units are required to be 1-hour fire resistance rated construction. IBC 702 -Definition of Fire-Resistant Rating-"The period of time a building element, component or assembly maintains the ability to confine a fire,...as determined by tests, or the methods based on tests, prescribed in section 703" Furnish data indicating fire resistance rating and test or used 20. MC 708.4 Fire partitions shall be continuous-Plans do not show details for intersection 3 of fire partitions and floor/ceiling assemblies or details for intersection of fire partition and interior and exterior partitions. Item not addressed.—Furnish details 21. IBC 713.3.1 Furnish locations & data for fire-resistance rated wall penetrations 22. IBC 803 Plans do not indicate interior wall and ceiling finishes to be used and their classification. Furnish classifications (per ASTM E 84 )for wall and ceiling finishes. 23. IBC 804 Plans do not indicate interior floor finishes or their classification 24. IBC 1802.2.3 A subsurface soil investigation is required to determine ground water table, unless the foundation wall is waterproofed in accordance with 1807. Furnish a copy of the subsurface investigation report indicating whether the existing ground water table is above or within 5 feet below the elevation of the lowest floor level where such floor is located below the finished ground level adjacent to the foundation. 25. IBC 1805.5.6 Foundation drainage required installed in accordance with 1807.4.2 and1807.4.3 unless the foundation is designed to support the full hydrostatic pressure of un-drained backfill Furnish documentation indicating that the foundation is designed and constructed to support the weight of the full hydrostatic pressure of un-drained backfill. 26. IBC 1207.1 Furnish sound transmission data 27. Furnish basement floor plan Electrical—NEC 1. NEC 230 Additional data required for electrical service: A. Disconnecting means B. Size of disconnect(s)—Load calculations C. Individual or grouped meters/disconnects D. Location of service E. Location of service panels 2. See# 10 Above Exterior Egress Lighting & emergency power data required 3. NEC 210.12 Identify Arc Fault protected outlets 4. NEC 210.8 Identify GFCI protected outlets 5. NEC 210-52 (E) Outdoor outlets required for grade level units Furnish Electrical data requested in 1 thru 5. Plumbing—IPC 1. IPC 106.3.1 Furnish riser diagram 2. WPCA Furnish data for house trap location, size, venting and cleanouts 3. Hot water? 4 4. See# 17 above Fire separation penetrations 5. IPC 314.2.1 Furnish details for condensate disposal (2nd floor A/C units) 6. IPC 405.3.1 Plans not to scale, furnish scale drawing for typical bathroom fixture location 7. IPC 424.3 Furnish data for shower valves 8. IPC 604 Furnish design calculations to determine compliance with sections 604.3, 604.4, 604.5, 604.6, 604.7 9. IPC 608 Furnish backflow prevention data as appropriate 10. IPC 702 Sewer, drain and vent pipe required to meet requirements of section 702 Furnish Plumbing data requested in 1 thru 10. Other Requirements 1. Other Department Approvals Sign Off Sheet: Fire Marshal approval Planning& Zoning approval WPCA approval Public Works approval Furnish department sign off sheet with approvals 2. Fee Due - $4424.89 per building Application Fee Due Vernon D. Vesey II Building Official Cc: Smith Engineering I Smith Engineering 128 Jupiter Point Road Groton, CT 06340 ;860) 446-1636 September 1, 2009 Town of Montville 310 Norwich- New London Turnpike Uncasville, CT 06382 Attention: Mr. Vernon D. Vasey II - Building Official Subject: Apartment Buildings - 36& 46 Platoz Drive - Uncasville, CT 06382 Gentlemen: This letter report is to inform youthatI have Performed a structural analysissis of the 10" concrete foundation walls of the subject buildings and determined that the walls will safely withstand the full lateral hydrostatic pressure of the undrained backfill soil. Therefore, according to IBC Section 1805.5.6 a special drainage system is not required. If you have any questions please contact me. Respect i • ,aNA t. 41. R 'SI oot Sititl\Engii'. ing r •>r� �F f.O��v�y£ .o.t„r R1lT taJ' •t /OPAL t# Smith Engineering 128 Jupiter Point Road Groton, CT 06340 ,860) 446-1636 September 22 2009 Town of Montville 310 Norwich - New London Turnpike Uncasville, CT 06382 Attention: Mr. Vernon D. Vasey II - Building Official Subject: Apartment Buildings - 36 & 46 Platoz Drive-Uncasville, CT 06382 Gentlemen: This letter report is to inform you that on this date I have performed an investigation and analysis of the soils in the area adjacent to the basements of the subject buildings. Test holes were excavated with a backhoe to a depth limited by apparent bedrock. The attached sketch provides all the details of the investigation. The soil adjacent to both foundations was found to be dry with no positive indications of a water table or moisture above or within 5 feet below basement floor elevation. As a result waterproofing of walls in accordance with IBC 1807 is not required. If you have any questions please contact me. Re )Iy •• s, Air,p l erti th L 6 erinb. ° ''ti f'DaAL �i4 /1 I.S0401 4 -rzor Per =-1 ollko. / 1 t-kerr , /t•. er ,...---- .---1 44--------- I----. — ' ,.•! ...0•-e-- 1 e 1=1,grok,vrtz— _ ...., 19.420.r 1=14.44 0 woe.," ..res lijk_4_611111r l'hfitr! 0-VA ‘491116.'' 71 ' reim.41/4) —red:woo 11/21 114.k.,1; ‘raCt1641--4" " 4 k / VA _ 43_11 .......5 . A+ [/ 1 1 1 , ' 4,11101.0_ fol&04 13' 1 rr.+440 64 4.44414'"4 '-'' rn-r 5 4440.. 614.1.040044-$ r""t'S oc„A."4, 11/430.15 ,4 **-0444,6 Perouwolre.16 lit Wile#1104106014 4,,.-- Woggle. I 6.4.,,'1 4,,IA IlitotM6K to OK A .....40004 worltig I ---r-bm'srrl'. °1-1' 1 I Z-- --r—elr- r=1—r '1 Notes: I.Apparent Bedrock 2.Thin Intermittant Trace of Mottled Soil 3.Suggest Site Designer Design Swale Trench sm.,. 3 ,......."1„:"Z'o i % t',#.4,4'CA. -..' fr. :CI 1...4` 4' ' • t I ri...43 LP Ce--r- . A' ‘0,..,,,s • : * iii•_ow ACI 87.52 til. c ,—. I' 4°°' eZ".e.LACOrd,10 er 7/Z-zi° 7 i 1 Smith Engineering RECEIVED 128 Jupiter Point Road Groton, CT 06340 W;-1 i 1 3 2009 ;860) 446-1636 BUILDING DEPT. September 29, 2009 Town of Montville 310 Norwich - New London Turnpike Uncasville, CT 06382 Attention: Mr. Vernon D. Vasey II -Building Official Subject: Apartment Buildings - 36 & 46 Platoz Drive - Uncasville, CT 06382 Reference: Your Letter to Mr. John Mandes dated June 30, 2009 , Same Subject Gentlemen: Acting as an agent for Mr. Mandes I am forwarding the information requested in reference letter, high-lighted in yellow, on subject buildings for the Building& Structural - IBC Section. The Electrical & Plumbing Sections will be addressed by others. Itemization numbers of information provided agree with your numbers used in the reference document. Building& Structural- IBC 6. IBC 1107.7.1.1 - Added details for Type A& B bathrooms and are shown on Drawing DI. 8. IBC 1006.1 - Note #17 added to Drawing A 1. Design by others. 9. IBC 1006.3 - Note#17 added to Drawing Al . Design by others. 11. IBC 1009 - Dimension details on Drawing A 1 & A3 have been revised. 12. 1010 - Guardrail heights changed in Item #11 above. Data furnished on slip resistant ramp material on Drawing Al, Note #19. Ramp lies under 2°1 floor deck and is protected against snow and ice. Total rise for ramps has been shown on Drawing A 1. ✓15. IBC 1209.3 - Access to mechanical and electrical area is shown on Drawing S I. 18. [BC 711.4 - Drawing S2 has been revised to take care of IBC 711.4 requirements. For penetrations see Drawing Al Note #20. 20. IBC 708.4 - Intersections of fire partitions and floor/ceiling have been added to Drawing D I. J22. IBC 803 - Wall & ceiling finish classifications have been added to schedule on Drawing A2. V24. IBC 1802.2.3 - See Letter Field Report dated 9/22/09 by Smith Engineering for soils analysis. 1. Smith Engineering /25. IBC 1207.1 - See Letter Report dated 9/1/09 by Smith Engineering on foundation wall design analysis. If you have any further questions or I can be of further assistance please contact me. Thank you. Respectfully your' F HCl v7 • �// 0'f461,0 Robert S. Sn .i , , I _ Smith Engint rg No. 8752 .4\r. � :tol°tia/ +14va cc: Mr. John M. ,,, $ 1 t'qF 1'86 '4 Town of Montville ti!c rt ��1 310 Norwich-New London Tpke. . -Ii Uncasville, Ct. 06382 \s ). 10/23/09 John Mandes 11 Devonshire Dr. Waterford, Ct. 06385 Re 36 &46 Platoz Dr., Uncasville On 5/11/09 I sent you a rejection of your applications dated 4/21/09. On 6/19/09 you delivered amended plans and additional information regarding your application. I have reviewed the changes and additional information. Your amended applications are being rejected as follows: Please note: My first rejection notice was improperly numbered and I have corrected the numbering. Items highlighted are still missing information or otherwise not code compliant. Requests for additional information or changes are in bold print. Building& Structural-IBC 1. IBC 106.1.1 Applicable Code(s),Use Group,Type Construction not indicated 2. IBC 106.1.3 Exterior wall envelope compliance 3. IBC 1603.1.5 Earthquake load design data required 4. IBC 1607.7.1 Handrail & Guardrail Load design data required 5. IBC 1601.1.1 Method or Standard used to determine wind loads not indicated on plans 6. IBC 1107.6.2.1 IBC 1107.6.2.1.1 IBC 1107.6.2.1.2 IBC 1107.7.1.1 All units on the grade floor level are required to be either type A or Type B accessible units. Only one unit is indicated as accessible and the data furnished is incomplete. 1107.2 Type A& B units shall comply with the applicable portions of chapter 10 of the 2003 ICC/ANSI IBC 1107.3 Type A and B units shall be accessible including toilet and bathing rooms, kitchen,living and dining areas,and any exterior spaces. Furnish details with dimensions and other data for all accessible futures,features and spaces for both Type A and Type B units. 7. IBC 907.2.10.1.2 Smoke detectors not properly located 3 of fire partitions and floor/ceiling assemblies or details for intersection of fire partition and interior and exterior partitions. Item not addressed.—Furnish details 21. IBC 713.3.1 Furnish locations& data for fire-resistance rated wall penetrations 22. IBC 803 Plans do not indicate interior wall and ceiling finishes to be used and their classification. Furnish classifications (per ASTM E 84 )for wall and ceiling finishes. 23. IBC 804 Plans do not indicate interior floor finishes or their classification 24. IBC 1802.2.3 A subsurface soil investigation is required to determine ground water table,unless the foundation wall is waterproofed in accordance with 1807. Furnish a copy of the subsurface investigation report indicating whether the existing ground water table is above or within 5 feet below the elevation of the lowest floor level where such floor is located below the finished ground level adjacent to the foundation. 25. IBC 1805.5.6 Foundation drainage required installed in accordance with 1807.4.2 and1807.4.3 unless the foundation is designed to support the full hydrostatic pressure of un-drained backfill Furnish documentation indicating that the foundation is designed and constructed to support the weight of the full hydrostatic pressure of un-drained backfill. 26. IBC 1207.1 Furnish sound transmission data 27. Furnish basement floor plan Electrical—NEC 1. NEC 230 Additional data required for electrical service: A. Disconnecting means B. Size of disconnect(s)—Load calculations C. Individual or grouped meters/disconnects D. Location of service E. Location of service panels 2. See# 10 Above Exterior Egress Lighting&emergency power data required 3. NEC 210.12 Identify Arc Fault protected outlets 4. NEC 210.8 Identify GFCI protected outlets 5. NEC 210-52 (E) Outdoor outlets required for grade level units Furnish Electrical data requested in 1 thru 5. Plumbing—IPC 1. IPC 106.3.1 Furnish riser diagram 2. WPCA Furnish data for house trap location, size,venting and cleanouts 3. Hot water? 4 4. See# 17 above Fire separation penetrations 5. IPC 314.2.1 Furnish details for condensate disposal (2nd floor A/C units) 6. IPC 405.3.1 Plans not to scale, furnish scale drawing for typical bathroom fixture location 7. IPC 424.3 Furnish data for shower valves 8. IPC 604 Furnish design calculations to determine compliance with sections 604.3, 604.4, 604.5, 604.6,604.7 9. IPC 608 Furnish backflow prevention data as appropriate 10. IPC 702 Sewer,drain and vent pipe required to meet requirements of section 702 Furnish Plumbing data requested in 1 thru 10. Other Requirements 1. Other Department Approvals Sign Off Sheet: Fire Marshal approval Planning&Zoning approval WPCA approval Public Works approval Furnish department sign off sheet with approvals 2. Fee Due - $4424.89 per building Application Fee Due Vernon D. Vesey II Building Official Cc: Smith Engineering 2 8. IBC 1006.1 Means of egress illumination not indicated on plans 9. IBC 1006.3 Emergency power for means of egress illumination not indicated on plans The information furnished by your engineer indicates that means of egress lighting is not required per IBC 1006.1 exception#3. Exception#3 addresses areas WITHIN the dwelling units. Means of Egress lighting is required,including the exit discharge. Indicate means of egress lighting on plans. Indicate emergency power for means of egress lighting. 10. IBC 1009.5.2 Exterior stairs required to be protected from accumulation of snow or ice 11. IBC 1009 Handrail & Guardrail and Stair data insufficient to determine code compliance IBC 1012.1 Guardrail height required to be 42"-Plans indicate 34" for both guardrails and handrails 12. IBC 1010 Ramp data insufficient to determine code compliance IBC 1010.10 Per IBC 1012.1 Guardrail height required to be 42"-Plans indicate 34" for both guardrails and handrails IBC 1010.7.1 Furnish data for slip-resistant material on ramp surface IBC 1010.7.2 Ramps are required to be protected from accumulation of snow or ice.Indicate how you plan to accomplish this. ICC/ANSI 405.6 Indicate total rise for ramps 13. IBC 1203.2 Attic ventilation required 14. IBC 1209.2 Attic access required 15. IBC 1209.3 Show location of and access to mechanical equipment and electrical equipment Data not furnished-Furnish data 16. IBC 2304.11 Protection from decay and termites shall be provided by use of naturally durable or Preservative-treated wood 17. IBC 711.3 Floor assemblies separating R-2 dwelling units required to be 1-hour fire resistance rated construction. IBC 702 -Definition of Fire-Resistant Rating-"The period of time a building element, component or assembly maintains the ability to confine a fire, as determined by tests,or the methods based on tests,prescribed in section 703" Furnish data as to how this fire resistance rating was determined 18. IBC 711.4 Supporting construction shall be protected to afford the required fire-resistance rating of the horizontal assembly supported. Item not addressed - Section 711.4 referenced in#17 of engineer's response, where he states "There are no penetrations in the fire partitions." Section 711.4 deals with continuity of horizontal assemblies and protection of their supporting structure.711.5 & 712 deal with penetrations in horizontal assemblies. Furnish details for penetrations thru horizontal assemblies. 19. IBC 708.3 Fire Partitions separating R-2 dwelling units are required to be 1-hour fire resistance rated construction. IBC 702 -Definition of Fire-Resistant Rating-"The period of time a building element,component or assembly maintains the ability to confine a fire,...as determined by tests, or the methods based on tests,prescribed in section 703" Furnish data indicating fire resistance rating and test or used 20. IBC 708.4 Fire partitions shall be continuous-Plans do not show details for intersection Town of Montville 310 Norwich-New London Tpke. f ; Uncasville, Ct. 06382 Building Department 860-84 8-3 03 0-Ext.3 82 November 2,2009 Smith Engineering 128 Jupiter Point Rd. Groton,CT 06340 To whom it may concern Please note that on Oct, 13,2009 our office received a letter with regard to 36&46 Platoz Dr. and in response to comments on the plan reviews at these addresses. The following items are still at issue: 1. Item 6-All bathrooms on the first floors of these units must adaptable and sized accordingly for turning radius. 2. Item 11 -Handrail height is not identified. Show on drawings that the baluster spacing such that a 4" sphere cannot pass through. 3. Item 12-The ramp is not protected from ice and snow as the deck above allows water to pass through. 4. Item 18-There is no detail 6 as referenced on drawing S-2.Identify method and materials for each type of wall penetration. 5. Item 25—Verify foundation wall thickness. If you have any further question please contact us at our office at 860-848-3030 Ext. 382. Thank you. Respectfully Yours 5 David M.Jense eputy Building Official cc:file CV Smith Eng9 ineerin • � � � 128 Jupiter Point Road DEC - 3 21109 Groton, CT 06340 December 1, 2009 (860)446-1636 • ice of Tle Mayor Town of Montville Town of Montville 310 Norwich-New London Turnpike Uncasville, CT 06382 / EEjVE51 Attention:Mr. David M. Jensen-Deputy Building Official D E C 0 7 2009 Subject: Apartment Buildings- 36&46 Platoz Drive-Uncasville, CT 06382 BUILDING DEPT. Reference: Your Letter to Smith Engineering dated 11/2/09- Same Subject Gentlemen: Acting as an agent for Mr. Mandes I am forwarding the information requested in reference letter. Itemization numbers of information provided agree with your numbers used in reference letter. Electrical and Mechanical information will be provided by others. 1. Item 6-All bathrooms in Type A units comply with ICC/ANSI A117.1 Section 1003.3.2 and have"turning space"complying with Section 304. Type B bathroom units shall comply with Section 1004.11.1 and provide"clear floor space"complying with Section 3053 which has been provided. Type B bathrooms do not require a"turning space". 2. Item 11 -Handrail heights have been shown on Drawing Al and A3. Baluster spacing has been revised. See Addendum#1 attached. 3. Item 12 - See Addendum#2 for protection against ice and snow. 4. Item 18 - See Addendum#3 . Penetration information shall be submitted by others. 5. Item 25 -Drawing SI shows"as built"information submitted at time of foundation repair took place which shows dimensions. If you require further information please contact me. Thank you.. f co..4.F ; ._, rVery trul yo , deito/ l�Irr__ zi t i44—__ tg. 872 * 'O e' . Smith, I ii,4yj'. F to? cc.; Mr. John Mandes �,�#at Egg v_____h_ : .. a - - i--- --.;• 1 ! i L RECEIVED . r -, -; !:- -----!- -tr--1 i••—q-÷---- ------4-----. • ---- ---..". --..—1.__.I BUILDING DEPT229 , , -_,, , , ! „ , 1 f Hi HI j1 „ ! 1 . i : ., ; • I . ! i . . H , , i ! 1 1 H 1 1 I 1 - • , i i I t ii ii iiii . ii 1 ! , : • - • 1,---ii i_f_j .._ t _ _l_rir It.. LI !..._ 1_,,. i4 . ....... ..;_L___i____ii_.4 ____4 4z. li_ii____-, 11 Lii li ___1 ! II i ! - • : 4_ i -1 IT-1 - -I 1---1 r . El —1 1 ---- -----7-- ---1-- --F — L Li..._.;.. ..._ __ __1_4_ 1 14 1_1 J 1 1 I 1 i i }" - t ......_.....____, ! 1 i ! 4-- • , _ IN r i ''12'44 J• (Ofte Vi f. C)IV 6'al _ t 104:114 I A: IAILAJIMPAS-40 :.. . i I tidkIt I I I • 1.- (._._ i ...-----"! ..„... I .1-1 I I 1 i 1 J ---4.,"1„..-11 : s . ,i. "* i ; 1 i ..i—, ; 1 I I 1 ! ..4 i• i i----- 1 I I f 4 1„ fl 1 1-- . ) -.I- . .,..,.., 0 - i)f ----11 if •4.,i..--- .. 1 , i .,. ,,,,,,,,Hi. - „Ay . . . _ , , s ,.....,,...... ,,. , i I 4 t471 Ct Iji , , ,.... ft r I . 044m. to —i 1 ..----"----3-....."1 r' , i t ,....------------- /e /ay t , ._---- . t i -----"' .1'-'• rj ...,- ...-- I 1 1 eds. et.---r- Thm.c> 5fr A i rz,ux 0 Ls? M•r•li t I . PLAci—er3 171mA 4-, --7.---' ki T"5 3....rr 2/s/10 RECEIVED DEC 0 7 2009 BUILDING DEPT. fccir ii)ecks With 12' -.)And ifi- On-(filter Joist Spacing lleck, F-11 _ P 1 _- _-•__ -- -------- - _ - ---- v --------- / ? 11 , 8-1/16 1 1:,.._ '-------------'-"- ''''11- — -----''---1:7--k.t. --s,,.,- .-..-. ''''''. :--1-7' 1''---,;;;;" L _ i F- 0#fo-,-•-% -,-.4,,,-_,..-,-4.:'!.. Lead*of Eitacke ., 01 i IT Li-sir , ,4440110 ,_ .- - ; - ,,„. IA , ii. ... Camila&racket , --1 14- CA1Ttre Bracket I 'Joist --— - rOriva Cover/F-Bratkial V-Panel i 1 4o-1/4-ctir --1 3-Vir pr''' ; Nut*Citi *ararket V-Partei J,:416111tOgldi IS Notes: Use under 2nd deck porch over handicapped ramps to prevent ice& snow buildup. TimberTech DrySpace material is supplied by TimberTech-894 Prairie Ave. - Wilmington, OH- 1-800-307-7780. Contractor shall provide a installation shop drawing. Installation shall comply with manufacturers recommendations. 41-)CD ‘-.)IV\ .2"-.• "440,...-is..-. ..„ /I Usi A,... co:TO 1411C- . • i., A t., 4001 40" -1 tio 752 i .0•"." .._ * 0 4,,, 41 }/44e;>.4t4PISTO't +.4. --' 437-71;arli(%.‘ ..,, 45 WI rr.k -r...„---ocs, — .."2....,,T-4,0 i C....-1- /Z///0 • i i% /6ct ------- - _ ---- — RECEIVED DEC 0 7 2009 BUILDING DEPT. I Notes: Electrical&Mechanical contractors shall submit catalog cuts and/or shop drawings for all penetrations into or through fire wall, fire barriers, fire partitions, smoke barrier walls and fir/floor/ceilings. Penetrations shall comply with the requirements of IBC Section 712. Kin / - . * `°tom. ` ./0/4t. � ./0 t-n # fid Town of Montville 310 Norwich-New London Tpke. I ' Uncasville, Ct. 06382 Building Department 860-848-303 0-Ext.3 82 December 11,2009 Smith Engineering 128 Jupiter Point Rd. Groton,CT 06340 Dear Mr. Smith On Dec. 7,2009 our office received a letter with your responses to our letter of rejection dated Nov.2,2009 on the plan review of the proposed structures at 36&46 Platoz Dr. Please note that items 2 thru 5 of your responses are acceptable and address those issues. Your response to item 1 is,however,further rejected.All bathrooms in the type B units must be adaptable and sized accordingly with regard to clearances for fixtures. If the doors are to swing into the bathrooms as shown on the drawing,then they encroach on the required fixture clearance space.Note, if you choose to reverse the doors,then the approach to these doors must be addressed per 404.2.3.1 of ANSI A117.1-2003. Please make the necessary changes and forward to our office for further review. Thank you If you have any further question please contact us at our office at 860-848-3030 Ext. 382. Thank you. Respectfully Yours 47 l David M.J nsen/Deputy Building Official cc: file Dec. 11. 2009 11 : 30AM No. 1062 P. 2 Type B — Opt. A Toilet Rooms • 000rr cannel a.Yf eto door Poor epaee raqukyingta tun,,iq oo •A•ee oompIyk�bilin prwld•d bey$nd twin. — • I(n.•and los MIYMe•e&uded In — el•a,roa•peu Y maw.. • Char Moor ipso,earl w•rlep. -, r..,, • • Mud provke r•Nloro•mnl fet .. Arcs ynbl5PM • ReWwe me Inor ItTdrodNi 'Penedo(Rpm*.es enqd Y INS i MOM do••m wMain the entyAnd moor elerei on ate:SHOW lev. de l•WL Lprcvi•• renter N Door iJy.� =' �j f end detwer nal required + 9 ;�1�r';,f'�1 • l! _ I Type B — Opt. A Toilet Room ■ Clear floor apace to be centered on lavatory.Cabinetry allowed as long as removable.eta es described In Type A uniL • Water Closet centerline to closest fixture to be 10' minimum on the aide opposite the direction of approach, and 15'minimum on other elde.centerline to wall lobe • Bathtubs with parallel approach are 60"minimum In length and 30'minimum In width.Lavatories at control end to have 305(.40 dear floor space for parallel — -- • approach. • Provide reinforcement for future grab bar Installation. Type B — Opt. A Kitchens • U-shaped kitchens with counters,appliances or cabinets on three continuous sides to have 60' clearance,minimum.Galley kitchens to have 40' clearance, • Clear floor space centered on sink bowl, • Clear floor space positioned beyond swing of - - dishwasher door parallel or forward approach. Door,when open cannot obstruct clear floor space of sink or DW. • Clear floor space centered on cooktop. 23 i Dec. 11. 2009 11 :30AM No, 1062 P. Type B — Opt. B Toilet Rooms ■ Clear floor space to be centered on lavatory. — Cabinetry allowed as previously discussed. r Water closet centerline to closest fixture to be - — - 1 B'minimum on the side opposite the direction of approach,and 15'minimum on the other side. Centerline to wall shall be 18', • 30xA8 dear floor space required at control end — of tub. Type B-B Toilet Rooms —, ! t I - - Type B Opt. B Kitchens • U-shaped kitchens require Bo"clear between counter,appliances,cabinets. Galley kitchens require 40'minimum. - ■ Clear floor space centered on sink bowl. • Clear floor space beyond swing of dishwasher door, • Clear floor space centered on cooktop. 27 Dec. 11. 2009 11 :31AM No. 1062 P. 4 Type B — Opt. B Units ■ Maneuvering clearances provided at entry _ door, lever hardware required. • Interior doors 31-314"width, no hardware restrictions. • Exterior sliding door thresholds allowed to —be W high, 1;2 bevel, all others W max. height.Exterior changes in level shall comply with 303. Type B — Opt. B Units • Controls mounted on appliances and plumbing _ fixtures exempt from 15-48'rule. " Electrical,environmental,security,and intercom must comply with 309.2 and 309.3 ■ Laundry equipment requires clear floor space for _ parallel approach,centered on appliance. ■ Emergency escape window operable parts must comply with 309.3,309.4. Type B — Opt. B Toilet Rooms • Doors cannot swing Into clear floor space required for fixtures unless 30x49 clear floor space Is provide beyond swing. ▪ Knee and toe clearance Included In clear floor space at fixtures_ • Clear floor spaces can overlap ■ Provide reinforcement for future grab bars. • 'Powder Room'exempt as before (reinforcement,floor clearances)unless It contains the only lavatory and water closet on accessible level. 26 Dec. 11. 2009 11 :30AM d— S_,,z f w,,. 1062 P. 1 Type A Unit • A clear floor space per aecUon 305 poalUoned for parallel approach shall be centered at each laundry appliance ' Complying operable pada In One window,electrical, environmental,appliance,plumbing,security and Intercom operable parts shall comply wilt!Secllon 309, with exceptions. • Dedlsalod+we reeeptxre ouUels • Ono receptacle outlet above a langtb or countertop Uvl ie not =tit byr atUankengoapanneoaleeraDntueoere my.ng uet • Floor receptacle ouUeis • HVAC crrrusera • Cohea1 mounted on many fanny • If redundant controls,ono control In each apace not requln;d to be acceaalble I Type A Toilet Room At least one complying bathtub or shower, water closet, and lavatory shall be provided within a single area. ■ Doors shall not swing Into the clear floor space for any fixture,except where a clear floor space per section 305.3 is provided beyond the door swing. • Clearfloor spaces,clearances at fixtures, and turning spaces may overlap, Type A Toilet Room ( ' . k: +SIr : ! � (A -::r. :t.. ->S,. .'�_=.>n eta - 19 Smith Engineering 128 Jupiter Point Road Groton, CT 06340 (860)446-1636 December 17, 2009 Town of Montville 310 Norwich-New London Turnpike Uncasville, CT 06382 Attention: Mr. David M. Jensen -Deputy Building Official Subject: Apartment Buildings - 36 & 46 Platoz Drive-Uncasville, CT 06382 Reference: Your Letter to Smith Engineering dated 12/11/09 - Same Subject Gentlemen: Acting as an agent for Mr. Mandes I am forwarding the information requested in reference letter. The revisions to Type "B" Handicapped Baths is shown on Addendum#4 attached. If you require further information please contact me. Thank you.. Very truly yours, Robert S. Smith, P.E. cc.; Mr. John Mandes • _ V) 1-3 1/1 1 I ; ( -1 6 . 3 I 1 1 I r- 1 • 1 tVI pQ 4ri , , i _,..___. ___....._ ._ ***.az — ='..` "-rl IS Ili I Q , a i(: z 4 , - , , ..,..._., p 11 • --„..44. d f .v r + Vit ' si i •O �N- '- r, M # F�r * r . `R 1 _ r 4' i li t 11 1PI % — C/' 1 ► ' i Ell'. + - , r 9 1 - ! , i IP '-..‹.. .._.,_J . ._.. I- ,.., r "— ---