Loading...
HomeMy WebLinkAboutCorrespondence re: Building Permit Requirements 2006 Town of Montville Building Department 310 Norwich-New London Tpke. Uncasville,CT 06382 Tel. 860-848-3030,Ext.382 Fax. 860-848-7231 October 20, 2006 John Mandes 11D Evenshire Drive Waterford, CT 06355 RE: 36 Platoz Drive We have received a building permit application for the above referenced property. In accordance with Connecticut General Statute 29-263, your application is being rejected for the following reason(s): 1. No site plan submitted, required to show paring, utilities, grading 2. Permit fee to be calculated 3. Construction approval sign-off sheet not submitted with approvals 4. Worker's comp. affidavit not submitted 5. Dwelling units required to be separated by fire partitions in accordance with Section 708, provide details 6. Automatic sprinkler system required per section 903.2.7, provide construction documents 7. Smoke alarms required per section 907.2.10.1.2 8. No construction documents provided for the stairs and decks 9. No dimensions provided for the decks 10. No details or information on the handicap ramp 11. Electrical plans required 12. Mechanical plans required 13. Plumbing plans required 14. The dwelling units must be designed to meet the accessibility requirements of section 1107.6.2 15. Framing details required 16. Dimensions required for rooms and spaces 17. Interior door sizes not identified 18. Compliance with the 2003 IECC required to be submitted 19. Heat loss/gain calculations required 20. More detailed and accurate plans are required to be submitted in order to do a through plan review 21. First floor decks seem to indicate walls between the units, how do you access these decks? We will keep all documents received to date on file and renew your application when you have furnished all the required data. Tha . , oseph J. Summers Deputy Building Official Cc: File . • Smith Engineering 128 Jupiter Point Road Groton, CT 06340 (860)446-1636 November 9, 2006 Town of Montville Building Department 310 Norwich-New London Turnpike Uncasville, CT 06382 Attn: Mr. Joseph J. Summers, Deputy Building Official Ref: 36 Platoz Drive Gentlemen: This letter is in response to your letter dated 10/20/06 on the same subject and provides answers to your questions and comments. The item numbers below agree with your item numbers in your letter. 1. Owner to provide site plan. 2. Owner's responsibility. 3. Owner/Contractor responsibility. 4. Owner/Contractor responsibility. 5. All walls separating dwelling units in same building have a minimum 1-hour fire rating. This is shown in Section B-B on Drawing No. S2. Division walls are lined with 5/8" FR sheet rock board which is carried from ground floor through to the roof. Ceilings of ground floor units are lined with the same material. 6. Sprinkler subcontractor will design and obtain approval and submit shop drawings for sprinklers when applying for a mechanical permit. 7. Electrical subcontractor will submit shop drawings for smoke alarms when applying for electrical permit. 8. Additional design information has been added to Drawings A 1 & A2 on stairs and decks. 9. Same as Item 8. 10. Same as Item 8. 11. Electrical subcontractor will submit required shop drawings for electrical work when applying for permit. 12. Mechanical subcontractor will submit required shop drawings for mechanical work when applying for permit. 13. Plumbing subcontractor will submit required shop drawings for plumbing work when applying for permit. 1. Smith Engineering November 9, 2006 Platoz Drive 14. Dwelling units are designed to the requirements of Section 1107.6.2 & ICC/ANSI A117.1- 2003. 15. Framing details have been included on Drawing S2. 16. Additional dimension information has been included on Drawings Al &A2. 17. Addition door information has been included on Drawings Al & A2. 18. Energy Plan has been included on Drawing A3. It complies with the requirements in IECC 2003, Chapter 6 for Group R2 buildings. 19. Heat Loss/Gain calculations are not required when glazing area is less than 25%. 20. Additional detail information has been included on Drawings Al &A2 to assist for plan review. 21. Revisions to Drawing Al have removed the problem. If further information is required please contact me at (860)446-1636. Thank you. Very truly yours, €� SAL Robert S. Smith, P. . J N c 3 E'Tm COT -1 -0° 5. Wim rn ogcc > [ W `-3 O130 O SD ' d4 CR CD C. O a CD O Pr CD ° -1