HomeMy WebLinkAbout1997 - Voided Permit for Fireplace Work �! ,e TOWN OF MONTVILLE / O Building Department / 848-7166 APPROVED BUILDING PERMIT OR TRADES PERMIT For 180 Days Permit No: 13363-G Approval Date: 3/19/-- . xpiration Date: 9/19/97 Estimated Cost: 600 .00 Fe- - : 10 .00 PRF: C .O: Owner : Charles Wozniak - :d ss: 32 Posurgiel Lane Tel : 848-3828 Job Location: 32 Podurgiel Lape Code: 06 Contractor: Suburban Propane/DeRosier$ A re- : 232 Gallivan LaneTel: 848- 5510 Stick Built: x Modular Home: anufactur -d Home: Commercial : Addition: Garage: Car Port: Shed: Remodeling: Roofing: Siding: Fireplace: C 'mney: Windows: Pool : Demolition: Plumbing: Heating: Elecrical : Air Conditioning: Gas: x Patio: Porch: Deck: Reta ning Wall : New: x Repair/Replacement: Type of material uses/discri-tion install gas log unit in fireplace Size: Type of Heat: Fireplace: No .of Stories: No. Rooms: Breezeway: No. Baths: ► -rage: Use: I hereby certify that the proposed work will conform to the Basic Building Code and all other Codes as adopted by the State of Connecticut , and the Town of Montville. ) /' 7. � � Applicant 's Signature: !(� (2. � 'UrtiLCi'rit� �Y/L . 1..t 'Date: If signed by Contractor , type of license/regi tration & No: CTS 4 :36e-60e Of / ..f Building Official 's Signature:�. .�-� _;/ �A7 `_�� j :ate: c_e/g 7 Date of Health Dept . Approval : // �rDate of Zoning Approval : '/ THIS IS TO INFORM YOU THAT UNDER THE CONNECTICUT AMENDMENT OF THE BUILDING CODE, SECTION 119 .3 A CERTIFICATE OF OCCUPANCY IS REQUIRED PRIOR TO ANY USE OF THE STRUCTURE. A MINIMUM OF 24 HOUR NOTICE TO THE BUILDING DEPARTMENT IS REQUIRED FOR INSPECTIONS . TOW' UI' MONTVILLE Building Department Application for a Permit Owner: Okt.r/ VV() r1�cc Address: 1-2 lc)r(u ( La Pie_ Tel : Ws' 2 Job Location: 32 )cLr 1 LC(NG� f tJ Contractor: - a ,-C�„� PrQ -rnAddress: X 74 �i /lr VC-1 Tel : RVA---S77/6 Stick Built: Modular Home: Manufactured Home: Commercial : Addition: — Garage: _ Car Port: Shed: Remodeling: Roofing: — Siding: Fireplace: Chimney: — Windows : Pool : Demolition: Plumbing: Heating: Electrical : Air Conditioning: Gas: Patio: Porch: Deck: _ Retaining Wall : _ New: Repair/Replacement: Type of Material/job �P T rru2ne. description: / Loi `c F�nc, 111 s c� (l F-r,�� Piet, c ,,s L.61 Size: Type of Heat: Fireplace: No. of Stories: No. Rooms: Breezeway: No. Baths : Garage: Use: , Suburban Propane -Quantum 90 Maclsto.vp Road • P.O. Box 220 • Windsor.CT 06095 FAX 203-683-2703 Tom._ 203-298-7950 DATE: 3" /q-/ 7 JOB NAME: 1,t/0 z 1 i< STARTING DATE: 3-090- 17 CONTRACTOR'S AGENT: 6 hec j G.cc,,n oc.-t r i vl e. Sr. TO: CITY/TOWN OF CA,l'1 Cots IA.1 I e cr PLEASE BE ADVISED THAT THE ABOVE REFERENCED AGENT HAS BEEN AUTHORIZED TO OBTAIN A PERMIT FROM YOUR BUILDING DEPARTMENT FOR THE SPECIFIED PROJECT IN THE NAME OF THE CONTRACTOR. SIGNED a-c-e-.���.ce • LICENSE 1 308608 ' i -..' iJZ.,/ J.:J.:_i/ 00LI00:,:.': ..IJ.., '...1-11bl_lt-'bi--,II I 'h'I_IF-'PrtIL LI- PAciE CU -- .• - . . ...-..... -.—... —.—...----..-. . . . . --.. . . . ... . .. . , . • . • .: . . • • •. • '',, . • . . . ... . . . . • II, ...,. . . . 4 . fgI7 a• ? • . 114 ne • .;..- *n± 0. ,.. k . . . , 0 . a .. en .' 01 •:-;:• • E.: 13,.': i• , .. c w gi co i' 1 1.• . r... a. Z L4 '5 3:18 5 .,. ._,L,_ • ui.. cn . •S -, . > 11 \.........; C•4 0 K.q 4 I-4 OD w'''-• .: • 4. rc -,_'• '4, ...- c°R 2a; 1" - ... -go . N'! fE, _ _ . .. ..... ...-, owl, .ni. r.-ti g.er4u t46° rz hi . .... Olo 4,4 -,,- .,,i , • 7,- Cf)) '' . .. . . •-• ,r, z 01-1 1-1C0 0 0 . a .iia 0 o w 7, z (5 ' • .. ,. (7)_..„ . . . • . • . . .. ' . . ' • . rL. . nr:114130:47410;1‘,...,.:-...,:,. l'''' . -S. , . ' • • • “1: 4 • • • • . • •". . -•r . ; . • • • . '.! '_'EDGWICK GLOBAL TEL : 201-535-0591 Mar 03 '97 15 :59 No . 004 P . 01 0 ACQRD1 CERTIFICATE OF LIABILITY INSURANCE °03'-Mdr 9 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION s ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE $EDGGJICK OF NEW JERSEY, INC. MOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR — ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. 1- 3 BECKER FARM ROAD COMPANIES AFFORDING COVERAGE ROSELAND, NJ 07068 COMPANY A CIGNA PROPERTY CASUALTY INS. Cl INiuRED COMPANY SUBURBAN PROPANE, L.P. g PACIFIC EMPLOYERS INS. CO. P.O. BOX 206 CO WHIPPANY, NJ 07981 Carr COMPANY 0 CO RV AGES — "' THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE SEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POUCY PERIOD " INDICATED,NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS •- CERTIFICATE MAY BE ISSUED OR MAY PERTAIN. THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, 0 EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. (3 CO ` TYPE Of INSURANCE POUCY MUM MA POUCY EFFECTIVE PoUCY EXPIRATION UNITS LTR DATE(MM/Do/VY) DATE(MM/OD/YY) A DENERAL LIABILITY HDU G I 9 31496 3/1/97 311 /' U GENERAL AGGREGATE $ , ' ' ' P ' ' .' COMMERCIAL GENERAL UASILITY PRODUCTS•COMP/OP AGG $ 1 g 000, O" CLAIMS MADE OCCURPERSONAL A ADV INJURY I$ , r, r, ,, , r, r, OWNER'S L CONTRACTOR'S PROT EACH OCCURRENCE $ 1 ,000,00,: FIRE DAMAGE(Any one h r.) I 50,0 0 ' MED EXP(Any oro►Mnonl $ 5 r r, r, I AUTOMOBILE UABIUTY C: A ANY AUTO ISA HO 1881280 3/1/97 3/1/98 COMBINED SINGLE UMIT $ 1 ,000,00:' ALL OWNED AUTOS BODILY INJURY i c= SCHEDULED AUTOS (Per person) HIRED AUTOS 0BOOILV INJURY X NON.OWNEO AUTOS (Par socld. t) $ I- —. PROPERTY DAMAGE I I.J • OARAOE LIABILITY I EN AUTO ONLY•EA ACCIDT $ .- _ ANY AUTO OTHER THAN AUTO ONLY; r- EACH ACCIDENT i AOOAEGATE-1 I EXCEse UABIUTY EACH OCCURRENCE i _ UMBRELLA FORM AGGREGATE $1 - — ._ OTHER THAN UMBRELLA FORM I S WORKER/COMPENSATION ANDWC ETATU- OTH- I TORY UMITS ER B EMPLOYERS'LIABILITY _ WLR C4 2305388 3/1/97 3/1/98 EL EACH ACCIDENT $ 1 , 00,74513THE PROPRIETOR/ INCL I El.DIMEADE.POLICY UMIT S , 0,00 PARTNERSIE(ECUTIVE OFFICERS ARE; 1 MI. F.L DISEASE.EA EMPLOYEE i 1��0,00 OTHER - - ` " 1 0 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES/SPECIAL ITEMS BLANKET ON ALL OWNED AND LEASED VERTC'LES, oI ALL PREMISES ALL LOCATIONS AND ALL OPERATIONS U 0: MTwH81'T RY CONCERN CANCELLATION SHOULD ANY Of THE ABOVE DESCRIBED POUCIaS BE CANCELLED mom THE a: P3OnTION DAT! THEREOF, THE IaouIHO COMPANY WILL ENDEAVOR TO MAIL "I DAYS WRITTEN Nonca To Thu CBRTIPICATE HOLDER NAMED TO THE LEFT, CI BUT FAILURE TO MAIL SUCH NOTICE SHALL IMPOSE NO OBUOATION OR UASIUTI' CG. � OF ANY KIND UPON THE COMPANY, ITS AOINTI 0 REPRE TAllYEL ur AUTHORIZED REPRESENTATIVE ,,-•" ,�/ / o: I k IwZ.�. ACORD 26-8 (1/95) / I - - O ACORD_ CORPORATION 19$:" CEAT!$ /F- 03/19/97 CUSTOMER DELIVERY INFORMATION LPRT0015 DIST: 1120 UPD : DISTRICT NAME : UNCASVILLE , CT BILL START DATE : 01 /31 /97 CUST: 72074 SUB : 001 ZONE/LOCATION : 032/1365 RT HIST START DT : 01 /31 /97 STATUS :A ACTIVE PRED/OVERRIDE : U N UNPREDICTABLE NAME :CHARLES WOZNIAK MAP CODE - ADR1 : 32 PODURGIEL LANE CUSTOMER TYPE : B BULK ADR2 : ROUTING METHOD :WC N CITY: UNCASVILLE ROUTING CAPACITY: 116 STATE : CT ZIP: 06382-0000 FUEL TYPE : D01 LAST DEL DATE : 00/00/00 PHONE : (860) 848-3828 PRICE CODE : 43 1 . 719 LAST DEL DD : 00000 NAT/ACCT LOC : 0000 SPECIAL PRICE : 0 . 000 LAST DEL GALS: 00000 DELIVERY NOTES PRESENT WHOLESALE PRICE : $0 . 00000 LAST % FULL : 00 NO CREDIT NOTES EXEMPT\DISCOUNT CODE & DATE\DISC: . 00 OVERRIDE DATE : 00/00/00 T A X METER TAX GROUP/EXEMPT : 64/3 FEED TANK CUSTOMER : SUB : NON TAXABLE PERCENT: 0 . 00 NUMBER READ CODE : STATE/MUNIC/OTHER: 26/000/00 READING READ STAT : ON HIWAY FD: N ST : N MU : N READ DATE : HEAD CODE : OFF HIWAY FD : N ST : N MU : N PRICE CODE : METER STATUS MTD TAX PAID 0. 00 ALTITUDE ZONE . HOLD ALT + FUNCTION KEY FOR POP-UP WINDOWS OR USE PG UP/DWN KEY ; F9->END VIEW F2-BILL F3-HISTORY F4-RENT F5-ACTIV F6-USAGE CALC F7-FKEY INFO F9=END VIEW ,. . k 'I. 0"."' ''..•. .... . i1---, --------i'' • sill'htithiin propene 421-43(w' e.4---"\44: FAX .41, ...,..._ burban_Pro,pane 262 Callivan Line - P. 0, Box 385 t 1, usvil1e, CT 06382 ,,, DATE: .2,_ ,,,..',,. / ____ Z' NUMBER OF PAGES ( Including 'transmittal Form ) TO: ID we' c'F' {--(flt:th.(VI II e A: i4idolfr,iiel) FAX #: PlIONE 4: .. . . FROM: _bria i-- C l )," Lc> ty? C LI. .,..,........_________________ s, i FAX #: (860) 848-5517 PHONE tir (860) 848-5510 i CT oily: (800) 573-3757 MESSAGE: _P /1 4r ( : •- ..._-_------- r_ ! ..---- ..:_-... h--,,---- ! , si ii, ,, fL, 60). . i, . . • IAMI N • MODELS INDUSTRIES AS4OM / FIW4011/1 i. MS4OM & AS40WM / 1-1W4OWM I MS401N11,141 GAS LOG APPLIANCES ,---6- 4-,, InstaliatiorL Operation and Maintenance Manual ! 0 ! mAximum HEAT INPUT RATING! 40M0 BTU PER HOUR ' . , 1 CII4 THIS ApPLIANcE IS ONLY FOR, USE WITH THE TYPE OF GAS INDICATED ON THE HATING LABEL ATTACHED TO THE. APPLIANCE, THIS APPLIANCE IS NOT 'i• ONVEFITIBLE FOR USE WITH OTHER GASES. I THE DESIGN OF THIS _A.PPLIANCE COIVIPLIES WITH STANDARDS Z21.11.2 AND Z21,60 OF THE AMERI- CAN NATIONAL STANDARDS INSTITUTE AND IS SO CERTIFIED SY THE AMERICAN GAS ASSOCIATION. I IN ACCORDANCE WITH STANDARD Z2111.2, THIS APPLIANCE MAY BE OPERATED AS AN UNVENTED I HEATF,R WHEN INSTALLED IN A SOLID-FUEL BURNING FIREPLACE WITH THE FLUE DAMPER CLOSED, OR WHEN INSTALLED IN A ZCB, AZCB, MZCB, EVB3.6, ALVR, OH MEVB MANUFACTURED UNVENTED 1 FIREPLACE, FOLLOW THE APPLICABLE INSTRUCTIONS CONTAINED IN THIS MANUAL. (STATE OR LOCAL. CODES MAY ONLY ALLOW OPERATION OF ThIS APPLIANCE IN A VENTED CONFIGURATION CHECK YOUR STATE OR LOCAL COLJES.) 1 IN ACCORDANCE WITH STANDARD Z21,60, THIS APPLIANCE MAY BE INSTALLED IN A SOL1D-FUEL 1 BURNING FIREPLACE, WITH THE I''L,I,M.' DAMPER LOCKED OPEN'TO MAINTAIN A MINIMUM VENT OPEN- ING (AS SPECIFIED WITHIN THIS MANUAL), AND OPERATED AS A DECORATIVE GAS APPLIANCE. FOL- LOW THE APPLICABLE INSI Rue-nous CONTAINED IN THIS MANUAL. __________________ _______________,.............----------------,,,-,-....--,...o,r-a•-•..•,rve 2 ,2,..----4. 2.,-•-•.22e,,..,2,-,-.a,.....u..2.24-ua,... ,--.6......A... 4•CJap.,...,* NOTICE: IF A STATEMENT CONTAINED iN THIS MANUAL DOES NOT SPECIFY OTHERWISE, THAT STATE1 [ MENT APPLIES TO BOTH UNVENTED HEATERS AND DECOHATIVE GAS APPLIANCES. 1 ___I F THIS AIPLIANeNlii..Y BFINSfitLCED IN ANA.FTERIciARiiiT MAWUFACiiiiiIi6146-BIL ) HOW-E,WHERE NOT71 i PPOHIBITED BY STATE OR LOCAL CODES, INS1 ALL ONLY IN A SOLID-FUEL BURNING FIREPLACE OR I APPROVED VENTLESS FIREBOX ENCLOSURE (MANUFACTURED UNVENTED FIREPLACE) AS SPECIFIED 8Y THESLI INSTRUCTIONS: ( AFTERMARKET: COMPLETION OF SALE, NOT FOR PURPOSE OF RESALE, FROM THE MANUFACTURER. I VVAPNING: IF THE INFORMAnON IN THIS MANUAL IS INOT FOLLOWED EXACTLY, A FIRE OR 1 • EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. i . _________. . _17_ _7_,. .., ._, . ________________—___________-- — 00NOT STORE USE GASOLINE OR— OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. — WHAT TO DO IF YOU SMELL GAO • DO NO 1 TRY TO LIGHT ANY APPLIANCE , - DO NOT TOUCH ANY ELECTRICAL SWITCH; DO NOT USE ANY PHONE IN YOUR BUILDING. . IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEiGHBOR'S PHONE. FOLLOW THE GAS SUPPLIER'S INSTRUCTIONS. - IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE 0 E PARI IVIEi N T, — INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSIALLLR, SER- VICE AGENCY OR THE GAS SUPPLIER. I .._ i This is an onvented gas-fired appilents.e. It use:4. air (oxygen) from the room in which It Is installed. i 1 Provisione for adequate combustion and ventitatIon air must be provided. i i__-_—_— — - ..,__--...---- ----------1 AVOINAM0011-4,1WLi .A440'0* S • ---,— IMPORTANT INFORMATION MOOT.Y..,•.A.J+ aaaue!!.. This manual is the property of the gas log appliance owner. It contains information to be used before, during, and after the installation of the gas log appliance. The installer of the gas log appliance shouid carefully study this manual before Installing the appliance. Ali people who will be operating the appliance should also carefully study this manual. The installation of this appliance must conform with local codes or, in the absence of local codes, with the waist edition of the National Fuel Gas Code ANSI Z223.1.The installation and any service of the appliance must be by a qualified service person. After installing the appliance, the installer should describe the operation of the appliance to the people who viii be operating it, The appliance is equipped with a pilot light safety system that turns off the appliance it enough fresh air is not available. The operatIon of and the cleaning of the pilot light safety.system are explained in other sections at this manual. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has Peen under water. DANGER THIS APPLIANCE, AS ANY GAS-FIRED APPLIANCE, CAN PRODUCE POISONOUS CARBON MONOXIDE ALONG WITH OTHER COMBUSTION PRODUCTS. CARBON MONOXIDE, IN STRONG CONCENTRATIONS, CAN CAUSE SiCKNESS, SERIOUS PERSONAL INJURY AND DEATH. NOTICE: THE SYMPTOMS OE CARBON MONOXIDE POISONING MAY RESEMBLE THE FLU WITH HEADACHES. DIZZINESS AND/OR NAUSEA(SICK STOMACH FELLING). IF YOU HAVE THESE SYMPTOMS, THE APPLIANCE MAY NOT BE WORKING PROPERLY, GET FRESH AIR AT..c.*CEi HAVE_THE_AE,PLIANcl_retIELK ED ElY,A, QYALIFIEQ ac.7fiVic E EfflN SOME PEOPLE -- PREGNANT WOMEN, PERSONS WITH HEART OR LUNG DISEASE, ANEMIA, THOSE UNDER THE INFLUENCE OF ALCOHOL, THOSE': AT HIGH ALTITUDES — ARE MORE AFFECTED BY CARBON MONOXIDE THAN OTHERS. WHEN PROPERLY INSTALLED, USED AND MAINTAINED, THIS APPLIANCE SHOULD NOT PRODUCE CARBON MONOXIDE IN DANGEROUS QUANTITIES, HOWEVER SINCE CARBON MONOXIDE CAN BE DEADLY POISONOUS, THE INSTALLER AND ALL USERS OF THIS APPLIANCE SHOULD READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY'. DANGER:OPERATION OF THIS APPLIANCE ON GASES FOR WHICH IT IS NOT EQUIPPED MAY LEAD TO CARBON MONOXIDE POISONING. WARNING: THIS APPLIANCE CANNOT BE CONVERTED TO A GAS OTHER THAN THE TYPE FOR WHICH IT WAS EQUIPPED AT THE FACTORY. . The type of gas for Which this appliance is equipped is marked on the rating label attached to Me appliance, 'NAT" is nat- ural gas; "LP" is propane or propane butane, mixture GASEOUS FUELS ARE HIGHLY EXPLOSIVE IN CERTAIN CONCENTRATIONS AND ARE VERY FLAMMABLE, ANY GAS LEAKS IN THE PLUMBING SUPPLYING GAS TO THIS APPLIANCE CAN LEAD TO FIRE OR EXPLOSION. Sufficient space must be provided around this appliance to provide air for combustion and ventilation and to allow room for servicing. in order to provide the required swim, do not install this appliance in any solid-fuel burning fireplace with any dimension smaller than shown by table i. wc.nwetmern " _ TABLE -I (ALL DIMENSIONS ARE IN INCHES) APPLIANCE — MINIMUM FIREPLACE DIMENSIONS -- WITH OPTIONAL HEIGHT OF WIDTH OF WIDTH AT DEPTH OF ALS OR 1\43.11LOWER QFN1 OPN1 ft.r..9111) BEAR FIREPLACE (AS4.0M/HW40M/MS40M) ;:,r 7 20 17 (AS4OWMiHW4OWM/MS4OWM) 20 24 APPLIANCE WITHOUT OPTIONAL ALD_OR MO.laLQWER AS401v1111W40M/IviS40M) 20 20 liAS40WMil-IVV40WM/MS4.0WM) 20 U 24 it If this appliance is to be operated as an unvented heater, it (Mat be installed in a solid-fuel burning fireplace with the iiu damper closed;or it must be installed in a ZCB, AZC,B, NIZCB EVB36, AEVB, or MEVB manufactured unvented firepiace, Note: An unvented heater is an Unvented, self-contained. gas-burning appliance for connection to the house fuel aupoly system and for furnishing heat to the space in which instalied directly from the heater without duct connection. 2 8 . ,. e t • NOTICE: IF INSTALLED IN A ZCB, AZCB, NMZCR, EVt336. AEVB, OR MEVB MANUFACTURED UNVENTED FIRE- PLACE, THIS GAS LOG APPLIANCE CAN ONLY BE OPERATED AS AN UNVENTED HEATER. UNVENTED HEATERS ARE NOT PERMITTED BY SOME STATE OR LOCAL CODES. BEFORE INSTALLING A ZCB, AZCR, MZCB. EVB36, AEVB, OR MEVFI FIREPLACE FOR THIS GAS LOG APPLIANCE, CHECK YOUR STATE OR LOCAL CODES TO DETERMINE IF UNVENTED HEATERS ARE PERMITTED IN YOUR AREA. To INSTALL A ZCB. AZCB. MZCB, EVB36, AEVB, OR MEVB FIREPLACE, FOLLOW THE INSTRUCTIONS ACCOMPANYING THE FIREPLACE. iF UNVENTED HEATERS ARE NOT PERMITTED IN YOUR AREA,THIS GAS LOG APPLIANCE CAN STILL OF INSTALLED IN A SOLID FUEL BURNING FIREPLACE AS DESCRIBED BELOW, AND OPERATED AS A DECORATIVE GAS APPLIANCE. If this appliance Is to be operated as a decorative gas appliani;e, it must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.A permanent opening in the flue must be provided to vent the combustion products (flue gases). Any flue damper must be fixed in a manner that will maintain the minimum perma- nent vent opening according to chimney height as shown by table 2. Holes drilled in the damper or a screw or bolt fas- tened to the damper in such a manner as to prevent it closing more than enough to leave the minimum required vent open- ing are two ways of providing the permK cleat vent opening. If you are unable to determine the chimney height and the min- imum opening required, a permanent vent opening of 39 square inet ee will be satisfactory for any chimney height which is six feet or more: Do not install a decorative yaw appliance in a fireplace with a chimney height of less than six feet. Note A decorative gas appliance is tt self-contained,gas-burning appliance designed for installation only in a solid-fuel burning fireplace and whose primary function lies in themaesthetic effect of the flame �— --- MINIMUM SIZE OF PERMANENT VENT OPENING REQUIRED FOR DECORATIVE GAS APPLIANCES— CHIMNEY_MGHT_ 1pgs MANEN... ..YEK?'-+ E1l11N 6 FEET MINIMUM OF 39 SQUARE INCHES ct FEET MINIMUM OF 39 SQUARE INCHES 10 FEET MINIMUM OF 29 SQUARE INCHES 15 FEETMINIMUM OF 20 SQUARE INCHES 20 FEET MINIMUM OF 29 SQUARE INCHES f 30 FEET MINIMUM OF 29 SQUARE INCHES Do not install this,appliance in a bedroom or bathroom if the appliance is to be operated as an unvented heater.If the appli- ance is to be operated only as a decorative gas appliance, it may be installed in a bedroom or bathroom. Do not install this appliance in a fireplace whose flue is serving a separate solid-fuel burning appliance. If this appliance Is installed in a fireplace equipped with outside air facilities and the entrance point of the outside air is located in a plane above the bottom of tate fireplace, the outside air facility must be sealed at the point it enters the fire- place, Failure to do this may create a tee reizatri. DANGER: DO NOT INSTALL THIS APPLIANCE IN ANY AREA WHERE GASOLINE OR ANY COMBUSTIBLE OR EXPLOSIVE MATERIAL WILL BE USED OR SPORED. THE FLAME IN THIS APPLIANCE IS NOT ISOLATED FROM THE AIR SPACE IT HEATS AND IT WILL IGNITE FLAMMABLE VAPORS, OUST PARTICLES OR OTHER COM- BUSTIBLE MATERIALS THAT COME IN CONTACT WITH IT WHICH CAN RESULT IN AN EXPLOSION OR FIRE. DUE TO HIGH TEMPERATURES, THIS APPLIANCE MUST BE LOCATE() OUT OF TRAFFIC AND AWAY FROM FUR- NITURE AND DRAPERY, INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON_ WARNING: ANY CHANGE TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS- - � � .�".' COMBUSTIONVENTILATIONME. AND AIR t EQUIRENTSi _ _ As do all gas-fired appliances, this appliance requires fresh Crr(oxygen)for proper combustion and ventilation. Normal air infiltration into a building in which gas-fired appliances are installed will usually supplyance$involvedicient arrio it of eaair for proper ambustion and ventilation, but not in Fall cases.The number of gas-fired appliances ll any d)aadditicnare ial appli- ances ur devices which remove air from g the building, and the type of space in which the as-fired app talled must all be considered when determining whether normal air infiltration is ts Installed in lent or lif am addisptional fresh a� ®ir ill been needed for proper combustion and ventilation of the gas fired appliance(s) confined space are the terms used to describe the space in which gas-fired appliances may be installed. National Fuel Gas Code 2223.1 defines a confined spacer tali a space whose volume t sl ace than tGO cdbicteS tper 1,000 unconfined Stu oer hour at the aggregate input rating of all gas-fired appliances instal€ed int p space as a space whose volume is not less than 5r_1 (.taljkfeet per 1,000 Btu per hour of the aggregate input rating ufs.. gas fired appliances installed in that space, Rooms communicating directly with the space In which the app liance(s} are installed, through openings not furnished with dome, arra cdnsiderect part of the to-be-defined space. Asn+wtwHssonn-nawM Il V For example;three rooms in a house are adjoining with interconnecting passageways but no doors; each room has an 8 foot ceiling. One room is 16 x 12 feet, one k 12 x 12 feet, and one is 10 x 14 feet. The total volume of the three rooms is 3,808 cubic feet; (8 x 16 x 12) +. (8 x 12 x 12) e (8 x 10 x 14) 3,808 cubic feet. To be defined an unconfined space in this example, the total maximum aggregate input rating of all gas-fired appliances installed in the 3,808 cubic feet space must not exceed 76,160 Btu per hour: (3,808 divided by 50) x 1,000= 76,160 per hour. Normal air infiltration into an unconfined space will usually be adequate to supply the necessary fresh air for proper com- bustion and ventilation of the gas-fired appliances installed in that space, However, increased concern about energy cost. and conservation hes caused the use of new methods and materials in the construction and remodeling of many homes. These methods and materials which are intended to reduce heat loss often reduce normal air infiltration as well.Therefore, even though a space is considered unconfined space, additional fresh air from outside may be required for proper corn- bustiort and ventilation if the building is constructed unusually tight. Also the use of any additional appliance or device(such as an exhaust fan,clothes dryer,or fireplace)which removes air from the building will reduce the amount of available fresh • air obtained by normal air infiltration. YOUR LOCAL BUILDING INSPECTOR CAN BE CONSULTED FOR GUIDANCE IN DETERMINING IF AN UNCONFINED SPACE NEEDS ADDITIONAL FRESH AIR FOR PROPER COMBUSTION AND VENTILATION. WARNING: iF THE AREA iN WHICH THE. APPLIANCE MAY BE OPERATED IS SMALLER THAN THAT DEFINED A;. AN UNCONFINED SPACE, PROVIDE ADEQUATE COMBUSTION AND VENTILATION AIR BY ONE OF THE METH-- ODS DESCRIBED IN THE NATIONAL FUEL GAS CODE, ANSI 1.223.1, LATEST EDITION, SECTION 5.3. THIS APPLIANCE SHALL NOT BE INSTALLED IN A CONFINED SPACE UNLESS PROVISIONS ARE PROVIDED TO SUPPLY ADEQUATE FRESH AIR FOR PROPER COMBUSTION AND VENTILATION OF THE GAS-FIRED APPLI- ANCE(S) INSTALLED IN THE CONFINED SPACE. PROVISIONS WHICI-I PROVIDE ADDITIONAL FRESH AIR TO A CONFINED SPACE OR AN UNCONFINED SPACE MUST COMPLY WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODEC, WITH THE LATEST EDITION OF NATIONAL FUEL GAS CODE 2223.1. CONSULT YOUR LOCAL BUILDING INSPECTOR OR THE LATEST EDITiON OF NATIONA+_ FUEL GAS CODE Z223.1 if: YOU HAVE ANY QUESTIONS ABOUT FRESH AIR REQUIREMENTS FOR PROPER COMBUSTION AND VENTILATION OF GAS-FIRED APPLIANCES. CAUTION: BECAUSE WATER IS A PRODUCT OF FUEL GAS COMBUSTION, ALL GAS-FIRED APPLIANCES WILL PRODUCE SOME WATER VAPOR (HUMIDITY) WHEN FiRED, THE WATER VAPOR MAY COLLECT ON WINDOWS AND WALLS. ESPECIALLY IN BUILDINGS CONSTRUCTED UNUSUALLY TIGHT. PROVIDING ADDITIONAL FRESH AiR WILL REDUCE THE AMOUNT QF WATER VAPOR WHICH COLLECTS ON THE WINDOWS AND WALLS. THIS APPLIANCE IS EQUIPPED WITH AN 0i0S(OXYGEN DEPLETION SENSOR)PILOT LIGHT SAFETY SYSTEM THAT TURNS OFF THE APPLIANCE IF NOT ENOUGH FRESH AiR IS AVAILABLE. NEVER ATTEMPT TO ADJUST THIS SAFE- TY SYSTEM.iT WILL NOT OPERATE CORRECTLY IF TAMPERED WITH, WHEN USED WITHOUT FRESH AIR,APPLI- ANCE MAY GIVE OFF CARBON MONOXIDE, AN ODORLESS, POISONOUS GAS_ IF THIS APPLIANCE SHUTS OFF DURING OPERATION, DO NOT RELIGHT IT UNTIL YOU PROVIDE ADDITIONAL FRESH AIR, IF PERMANENT PROVISIONS FOR PROVIDING ADDITIONAL FRESH AIR HAVE NOT BEEN IMPLE- MENTED,THE ADDITIONAL FRESH AIR MAY BE PROVIDED BY OPENING A WINDOW AN INCH OR TWO WHILE THE APPLIANCE IS OPERATING. IF THE APPLIANCE KEEPS SHUTTING OFF DURING OPERATION, HAVE IT SERVICED. WARNING: THE ODS (OXYGEN DEPLETION SENSOR) PILOT LIGHT SAFETY SYSTEM IS NOT A SUBSTITUTE FOR PROPER INSTALLATION AND USE OF THIS APPLIANCE, FAILURE TO OBSERVE INSTALLATION AND USE GUIDE- LINES iN THIS MANUAL CAN LEAD TO CARBON MONOXIDE POISONING, FIRE Ole EXPLOSION. CLEARANCES AND EXTENSIONS The minimum clearance to any combustible item in front of this appliance should be no less than 36 inches from the face of the fireplace in which this appliance is installed. Any combustible mantel present on the fireplace facing of any fireplace in which this appliance is installed must not extend more than 12 inches from the face of the fireplace.Also;the combustible mantel must be at least 28 inches above the fireplace opening as shown by figure 1 unless an H285e Fireplace Canopy is installed as described by the following paragraph. If a combustible mantel is less than 28 inches above the fireplace opening ai any fireplace in which this appliance is installeo, obtain an H2853 Fireplace Canopy from your appliance dealer and install it on the fireplace according to the instructions fur- nished with the H2853 Fireplace Canopy. For any fireplace in which this appliance and canopy are both installed, the mantel extensions and corresponding mantel clrerances are as shown by figure 2. The mantel must lie in or above the dashed line shown by figure 2. (The mantel extension is the distance the mantel extends from the fireplace facing. The mantel clearance is the distance from the fireplace opening to the bottom of the mantel.) Any other combustible or noncombustible extension or trim extending from the fireplace facing of any fireplace in which this appliance is installed must comply with (1) local codes or, in the absence of local codes, with the latest edition of ANSI/NEPA 211 if the fireplace is an at-site-built masonry solid-fuel burping fireplace, or(2)the instructions provided by the fireplace man- ufacturer if the fireplace is a prefabricated factory-buIIt solid-fuel burning fireplace or is a ZCB, AZCB, MZCB, EVB36, AEVB. or MEVB manufactured unvented fireplace). 4 AEmw,Me4oM.4r2wM