Loading...
HomeMy WebLinkAboutFurnace and Air Conditioning 2009 Field Inspection Notice Town of Montville Building Department Address: 24 Podurgiel Lane Job Description: Propane Furnace, A/C in Attic Permit Number(s) M2009-0051 Permit Date: April 20,2009 Not Approved Approval INSPECTION Date: Deficiencies Special Date Conditions Gas test • 15 PSI OK 5/18/09 DJ • • • Final inspection for •• certificate of approval Rev.Date: 1/18/06 Page 1 of 1 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 MECHANICAL PERMIT Permit Number: M2009-0051 Date: 20-Apr-09 Map/Lot: 103/003-000 Owner ID: 5558000 Project Location: 24 PODURGIEL LANE Unit: Job Description: Install Propane Furnace with A/C in Attic Owner Name: Michelle M and Stephen M Ahlcrona Tenant Name: N/A Careof: 24 Podurgiel Ln Uncasville CT 06382- Telephone: (860)917-3813 Contractor Name: Bogdan Gutkowski Telephone: (860)229-8529 DBA: Central Heating Lic/Reg Type: 51 Lic/Reg No: 303207 620 East Main Street Exp Date: 30-Oct-09 New Britain CT 06051- Construction Value Permit Fees Construction Information Building Value: $0.00 Building Fee: $0.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Value: $9,000.00 Mechanical Fee: $72.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type: IRC Total Value: $9,000.00 Penalty Fee: $0.00 Permit Code: R5 C of 0 Fee: $0.00 Comments: Plan Review Fee: $0.00 State Ed Fee: $1.62 Total Fee Paid: $73.62 It shall be the owners reosonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING, MECHANICAL, ELECTRICAL PERMIT INSPECTIONS ❑ Footing -Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor framing ❑ Electrical Service CRS No: 0 ❑ Framing R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble V Gas Piping and leak test ❑ Fireblocking_Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation Certificate of .proval - - cat: .f Occupancy Building Official's Approval: /, {.`.trxy _ / 0 Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.:Ma(I)9—Z51 Type of Work Occupancy Type Permit Type El New Construction 0-Single Family 0 Building 0 Addition ❑Two-Family 0 PILimbing D Alteration I]Townhouseechanical 0 Accessory Structure 0 Electrical CRS#: Property Address: - r't -12C'cl u .- 4' ; F7( Lrt (Number) 'J (Street) (-Unit Job Description: ____/- b 17'/``'r /1 p✓opC 1-c- F ✓1 C (.._.L__9 `- ii w . / r a( i -/-4G- r Owner: S-� Oe'J� A)1 k_-,71,-, 4 Address: (lea,11 1l.//' LA / F> i_c4 , Cky: ULl. . State: f Zip Code: Q 6 3 13.. Telephone( O ) -_3 73'1_3 Applicant: ---e, - rr ay E' y s� e e q(c`/i lT e.t fir DBA: r!�%_,L 1-,-- .[ j � ` , Address: c3 /1 6 Y i /z7 ✓ 1 City: Je 6 r ; ! 1 l State:<''t Zip Code: 6 4o b ( Telephone( j9C-1 ) - e.:5-02 ;� Contractors -Complete the Following: y � License Type: _ License No.,3 �y �� ZZ,� Expiration �R= Date: � /3c /' I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. ❑ By checking this box,I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner!Agent Signature: =_ lt.„_ '4,.... Date: c)t) l> Constructiorf Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Ly (_,C. e-) d Mechanical Fee: i Electrical Value: i Gt c t Electrical Fee: Total Value: !( d (f) .. ED C) Penalty Fee: CofOFee: Plan Review Fee: State Ed Fee: Total Fee: visef August 2.3.2007 Town of Montville Building Department File Receipt Date: 20-Apr-09 Receipt No: 4402 Received From: Gutowski Inc. Job Address: 24 Podurgiel Lane Fees Collected State Educational Training Fee Cash: $0.00 Cash: $0.00 Check: $73.62 Check: $1.62 Check No: 9221 Short/Over: $0.00 Construction Value: $9,000.00 Demolition Value: $0.00 Received By Carmen Roberts ("GA Y\A JZ.AA (0/1 - tedr2/( ' Address: 24 Podurgiel Lane ITEM QTY S./UNITTOTAL Building Plumbing Mechanical Electrical BUILDING AREA New Construction SF $ 113.03 $ - $ - Basement,Finished - SF $ 22.96 $ - $ - Basement,Unfinished SF $ 12.40 $ - $ - Crawl Sapce - SF $ 9.30 $ Interior Renovations SF $ 35.09 $ - $ - $ - MANUFACTURED HOMES Ground Anchors SF $ 6.45 $ - $ - $ - Basement - SF $ 12.41 $ - $ - $ - Crawl Space - SF $ 9.31 $ - $ AMENITIES Kitchen EA $ - $ - $ - Full Bathroom - EA - Half-Bathroom - EA GARAGE Attached SF $ 54.35 $ - $ - Detached - SF $ 69.53 $ - $ - Under - SF $ 1003 $ - $ - Carport - SF $ 19.89 $ - MECHANICAL Warm-Air n Y/N $ - Hot Water n- Y/N $ - Electric n- YIN $ - Air Conditioning n- Y/N $ - ELECTRICAL SERVICE Upgrade Amps $ - Overhead,new -Amps $ - Underground,new -Amps $ - Subpanel EA $ 599.50 $ - Gen Set - EA $ 3,850.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonrywlifireplace - EA $ 7,096.65 $ - Masonry w12 fireplaces - EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2,692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck SF $ 43.07 $ - Porch - SF $ 149.38 $ - Sunroom - SF $ 176.90 $ POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - $ - Inground Pool - EA $ 21,373.44 $ - $ - Above Ground Round - EA $ 5,099.46 $ - $ - Above Ground Oval - EA $ 6,019.75 $ - $ - Pool Heater - EA $ 8,984.25 $ - InflatableTypePool - EA $ 1,550.00 $ - SHEDS w/o electrical SF $ 20.35 $ - w/electrical - SF $ 20.35 $ RENOVATIONS Roofing,Overlay SF $ 3.00 $ - Roofing,Strip&reroof - SF $ 4.00 $ - Roof Sheathing SF $ 1.31 $ - Siding SF $ 3.50 $ - Windows - EA $ 500.00 $ - Skylights - EA $ 1,051.10 $ - Doors,Exterior - EA $ 601.50 $ - Oil Tank,275 Gallon - EA $ - Oil Tank,550 Gallon - EA $ - MISCELLANEOUS CALCULATIONS $ 9,000.00 TOTALS $ - $ - $ 9,000.00 $ • PERMIT FEE CALCULATIONS Construction Value Fee Building - Plumbing - Mechanical y $ 9,000.00 $ 72.00 Electrical - Working before Permit Issuance $ - Certificate of Occupancy Fee $ - Plan Review Fee $ - State Education Fee $ 1.62 TOTALS $ 9,000.00 $ 73.62 Figures are based on the 2006 RS Means Residential Cost Data Short Form Job: Date: Aug 29,2007 4t1Orli Entire House By: Project Information For: i,1 f4.' / c.,_ LL i_ 1 -P � Design Information Htg Clg Infiltration Outside db (°F) 0 90 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 70 15 Fireplaces 0 Daily range - M Inside humidity (%) - 50 Moisture difference (gr/Ib) - 23 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond Coil Efficiency 80 AFUE Efficiency 0 EER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1116 cfm Actual air flow 1116 cfm Air flow factor 0.024 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0.00 in H2O Static pressure 0.00 in H2O Space thermostat Load sensible heat ratio 0.91 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) ranch 1152 47234 20865 1116 1116 side 0 0 0 0 0 Entire House d 1152 47234 20865 1116 1116 Other equip loads 0 0 Equip. @ 0.95 RSM 19822 Latent cooling 2106 TOTALS 1152 47234 21928 1116 1116 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 7th Ed. wrightsoft Right-Suite Residential 5.9.52 RSR32147 2009-Apr-07 08.09'07 ACCA C.\tdy Documents\Wrightsoft HVAC\Ranch.rrp Calc=MJ7 Orientation=N Page 1 STATE OF CONNECTICUT DEPARTMENT OF CONSUMER PROTECTION . , A PLUMBING&PIP/Sq 0:4414ED CONTRACTOR BOtbAN.GIIVO*SKI ii*Pg ...i' i CWV.AIM KENSINOt*.dt *37 ,; LIC./REG NO. . .,. -, ,. IVE,r; ,r.'- ..., EXPIRES ',c,,,,- :2=,. ' .;IT ,:. PLM.0279247-'dip;YOr - '..4,' - 10/31/2009 SIGNED 4#0,,.. •-e-r ___ DEPARTMENT OF CONSUMER STATE OF COapi.r2 ( .-- ,,,..44i-z!,goi,4i ONTRAcTOR LIMITED Sr. ...m „.., :34‘PROTECTION BOd 0"GUTIY141 SKI 11.4404Y,A14“..* 8, I •,_,Y:' .,13 .',di' C1601.37 KENOINtri‘-mV --!7- fivq-i. -,,eFfEC LIC./REG Na,.:-.::,„:...,,, _ 08/31/2009 41. (4‘;;A9/61/ I EXPIRES ;HM.0000173-S --..:_. ,, ...!wp•r „imp, SIGNED ..e lei - STATE OF CONNECTICUT DEPARTMENT OF CONSUMER PROTECTION ____„, ____ HEATING,PIPING t!.5,COOLINRIMLIMITED CONTRACT BOGpANGUAIWSKI _L,L__,‘:;:—.: ,i,,, *,,, •,,,,,-, ittiot*ery Ar414* KEIVINUTTst:CT 04037 , LIC./REG N0Q.-- ,i .;E IVE..,-.,., -, . EXPIRES HTG.0303207-k 0f:„y4.1/off #e:1•--- i 3/3 1/2 0 0 SIGNED •. Town of Montville Building Department • 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL Applicant is responsible for obtaining all of the required approvals. No permit will be issued until all the required signatures are obtained. SLI PcAtArc i(-E Lc \ Propert}iAddress pcpri fir`'_ -FA,-l�k_r _ � (c n � ►�� 11 Job Description - Required for all permits ® - At least one required for all permits ❑ -Required as indicated below Required Department Approval Permit Issuance Approval • Tax Collector _ -4,100etei-xtu y tl �9 Signature/date Comments: ® Planning & Zoning Com 4Q,JC--a^'1 4-02o/() Signature/date Comments:Fire Marshalq101 Signature/date Comments: I I ,� w� L L�� Health Department Required for properties with septic systems—Not required for Plumbing, Electrical, Mechanical, Roofing,Siding,Windows& Doors Signature/date Comments: J ® WPCA, Administrative /-6:-2e(Zjy'Required for properties on sewer Signature/ Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ State Dept of Transportation Required for Structures over 100.000 sq. ft. or with more than 200 parking spaces-Official copy of STC Certificate of Operation required—per CGS 14-311 Signature/date Building Department Review Complete Signature/date RprircdWovez er i,2008