Loading...
HomeMy WebLinkAbout12x22 Living Area in Basement 2008 TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 BUILDING PERMIT Permit Number: B2008-0240 Date: 29-May-08 Map/Lot: 084/118-000 Owner ID: 5384000 Project Location: 24 PEACHVALE DRIVE Unit: Job Description: 12x22 Living Area in Basement Owner Name: Zachary Maurice Tenant Name: N/A Careof: 24 Peachvale Dr Uncasville CT 06382- Telephone: (860)887-6419 Contractor Name: Home Owner Telephone: DBA: Lic/Reg Type: Lic/Reg No: 0 Exp Date: C21103L PILV lue Permit Fees Construction Information Building Value: $0.00 Building Fee: $0.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2005 State Building Code Mechanical Value: _ $0.00 Mechanical Fee: $0.00 Electrical Value: — $0.00 Electrical Fee: $0.00 Construction Type: IRC Total Value: $0.00 Penalty Fee: $0.00 Permit Code: R4 C of 0 Fee: $0.00 Comments: Plan Review Fee: $0.00 State Ed Fee: $0.00 Total Fee Paid: $0.00 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING.MECHANICAL,ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor framing ❑ Electrical Service CRS No: 0 • Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑ Gas Piping and leak test ❑ Fireblocking_Draftstopping INSPECTION REOUIRED UPON COMPLETION ❑ Insulation ❑ Certificate of Approval : .!itl ertiBuilding Official's Approval: ' Town of Montville Building Department Residential Plan Review Form Date: _t:LA1/ ifi z 6 Job Address: a -.as-AG-' A SLS Job Description: Your permit application is being rejected for the items checked off or commented on. The required information must submitted for review(two sets are required) (C.G.S.29-252a.) This list is offered as a guideline only. It is not meant to be all-inclusive for every permit application,nor is it meant to take the place of the State Building Code. SUPPORTING DOCUMENTATION MEMIPermit a••lication not com.leted FLOOR PLAN I - ' _ No.lans submitted or insufficient information wz _ Permit fee to be calculated Basement floor.fan re.uired Worker's co •.affidavit or worker's co ..certificate to be submitted EMI Second floor.lan re.uired _ 1_ Dimensions not.rovided or insufficient nu Co.v of contractor's re•istration or license re.uired Construction permitsign-ofTsheet required with appropriateMN Kitchen la out not.rovided approvals,it shall w Bathroom la out and s.ace clearances are insufficient be the a..licant's res.onsibili to obtain the re.uired si• azures _ 1111 Affidavit required from the holder of the registration or license authorizing you t= Atili a he s to not identified asize or insufficient dicatedt to a•.1v for a.ermit with their informationNMI Attic access location and size not indicated or insufficient Provide supporting documentation to show compliance with the 2003 MCCAttic access must be in a readil accessible location not over shelvin: (www,enereycodes o,)OR Use of room s not identified or unclear 11111111 • One-and Two-Family Dwellings with 515%glazing area to conform to the Plans re.uired for the existin_residence for each floor with dimensions requirements of section N1102.1 • Townhouses with 525% glazing area to conform to the requirements of WINDOWS&DOORS section NI 102.1 Door sizes not identified Two sets of construction documents required, this includes all engineering 1111111111 Window size&tA.e not identified • data,calculations and all other documentation 8106.1 III Emergency escape & rescue opening required in the basement or two code Documents are copyright protected,provide original plans or a letter from the com.liant stairs.er section 310.1 Indicate the re.uired li_ht and ventilation for each habitable room or s.ace desi: er authorizin_the du.lication of the.lans IIIField set of the approved construction documents are required to be picked up Indicate the bedroom e:ess window from our office and must be available on site durin•all ins.ections11111111 Construction documents shall be of sufficient clarity to indicate the location, __ E:ess window sill hei:ht not identified • nature and extent of the work.ro.osed as.er section RI06.1.1 III _ Window well details not.rovided or insufficient Window header size not identified or insufficient Construction documents do not match the orientation of the structure on the Door header size not identified or insufficient site.lan _ GARAGE and CARPORTS WIND LIMITATIONS No.lan submitted or insufficient information.rovided III 1111111 Submit supporting data to show conformance with the wind limitations (3 n•section re.uired second:ust • 110 .h DesignIII Opening protection between the garage and residence is not identified or needs to be identified(WFCM,chapter 3;WFCM,chapter insufficient.er section 8309.1 publication all 2;ASCE 7-2002;SSTD10-99 . Separation between the garage and the residence is not identified or insufficient Documents required to be stamped and signed byCT .er section R309.2 aT registered Professional Documents must be designed to either • Wood Frame Construction Manual,2001 edition ELEVATIONS No.lans submitted or insufficient information • ASCE 7—2002 edition 111111111Plans do not match the floor.lans En SSTD]0—1999 edition Finish:ade not identified or does not match the site.lap all Documents required to be stamped and signed by a CT registered Professional MN Buildin•hei:ht s not identified En:ineer if based on ASCE 7-02 or WFCM cha.ter 2 Dimension hei:ht of chimne 11111111Shearwalls not identified on the construction documents or are insufficient IIIIIII Roof.itches not identified _ Shearwall calculations re.uired 11111111 lin Ride connection not identified or insufficient BUILDING SECTIONS&DETAILS Roof-to-wall connection not identified or insufficient IMO Wall-to-wall connection not identified or insufficient Full buildin:section not.rovided or insufficient innWall-to-sillconnection not identified or insufficient Floor-to-floor hei:hts not identified IIII Provide engineering data for the piers to resist Additional sections and details re.uired loads,stam.ed and si• ed b a CT licensed del .rofelss onalshear and uplift Draftsto•an:details not.rovided or insufficient gravity, M_ Hold-down devices,location and tA.e not identified or insufficient INFoundation anchor sacin•not identified or insufficient STAIRS MIConstructiondocuments do not match the en•eerie•data submitted Stau not shown on the basement floor.lan 1111 Cold-formed steel framing shall be designedStair not shown on the second floor.lan 2001 edition in accordance with COFS/PM- Riser hei:ht not identified or insufficient Tread de.th not identified or insufficient Nosin•re.uired for closed riser stairs SITE PLAN Riser o.enin•can not allow the.assa:e of a 4"s.here Plans re.uired Winder stair—detailed.lans re.uired Plans do not match the buildin:.lans S.iral stair—detailed.fans re.uired Finish floor elevation not indicated Stair width re.uired to be minimum of 36"above the re.uired handrail hei:ht Handrail detail not.rovided or insufficient detail Distance from the.ro.ert line s to the structure not identified Structure dimensions not.rovided Guardrail detail not.rovided or insufficient detail Existing and proposed contours are not provided or insufficient Headroom hei:ht not identified or insufficient Footin:drain dischar:e not identified 36"landin:re.aired at the bottom of the stairs Utilities not provided(electrical,phone,cable,sewer,water,gas) 36"landin:re.uired at the to.of the stairs Delineation of flood hazard areas and design flood elevation is required per Frost.rotection re.uired,.rovide details and connections section R106.1.3 Private sewage disposal system to be identified along with all technical and soil data as per section R106.2.1 WALLS Stud size and spacing not provided or insufficient ' Grading is to slope away from the building,provide more detailed information Sheathing type not provided or insufficient Plan submitted is not the same plan that has been approved by the Zoning Department and/or Health Department Retaining wall—construction documents required FLOOR FRAMING Plans required showing joists,beams and openings I BF arine partitions not provided or indicated Retaining wall documents required to be stamped and signed by a Connecticut I I Registered Professional Engineer Framing direction not indicated or unclear Beam span&size not provided or insufficient FOUNDATION Joist span,size&spacing not provided I I q u No plans submitted or insufficient information Dimensions re i.ed Joist's over-spanned Beam over-spanned Wall thickness not identified Provide design data for all unaligned wall and floor bearing points Footing size not identified Point loads not identified on beam data Frost protection not identified or is insufficient Framing less than 18"to grade to be pressure treated or decay resistant Column type,size,spacing not identified or insufficient Waterproofing details not provided or insufficient Steel beam — must be stamped and signed by a Connecticut Professional Engineer LVL's—engineering data required I Joists—engineering data required Pier type,size and anchor details not provided or insufficient Engineered foundation plan required Crawl space ventilation,location,type and size not provided or insufficient Crawl space access,location and size not provided or insufficient Design loads not provided or insufficient 24-viredEe6ruary 6,2006 Town of Montville Building Depat tnient CEILING FRAMING TWO-FAMILY DWELLING UNIT SEPARATION(R317.1) Plans required showing joists,beams and openings Separation by 1-hr fire-resistance construction,provide a listed assembly Bearing partitions not provided or indicated Rated wall and/or floor assemblies shall be tight against exterior walls and to Framing direction not indicated the underside of the roof sheathing,provide more detail Beam span&size not provided or insufficient Supporting construction shall have an equal or greater fire-resistive rating, Joist span,size&spacing not provided provide details Joist's over-spanned Beam over-spannedTOWNHOUSE SEPARATION(R317.2) Provide designn datadata for all unaligned wall and floor bearing points One-hour rated assembly must have a listing for exposure from both sides(two Point loads not identified on beam data walls) SEteel beam— must be stamped and signed by a Connecticut Professional Common wall assembly must be 2-hr fire-resistance rated and listed Mechanical equipment,ducts or vents not allowed in common 2hr wall Engineer LVL's—engineering data required Electrical penetration detail required for common wa ll I-joists—engineering data required Common wall shall be continuous from the foundation to the underside of the Design loads not provided or insufficient roof sheathing Each individual unit shall be structurally independent ROOF FRAMING Parapet required or the roof decking or sheathing is of noncombustible materials or approved fire retardant wood for 4 ft on each side of the walls) Plans required showing rafters,beams and openings Bearing partitions not provided or indicated FLOOD-RESISTANT CONSTRUCTION(R323) Framindirection not indicated size not provided or insufficient Documentation required to be submitted for the connection,anchored to resist Rafteraam span,s zflotation,collapse or permanent lateral movement spa ,size&spacing not provided Delineation of flood hazard areas, floodway boundaries,and flood zones and Rafter's ovver-spanned the flood design elevation to be identified on the site plan(RI06.1.3) Beam over-spanned Provide design data for all unaligned wall and floor bearing points Elevation of the proposed lowest floor,including basement;in areas of shallow flooding (AO zones), the height of the proposed lowest floor, including Point loads not identified on beam data basement,above the adjacent highest grade shall be identified(R106.1.3) Steel beam— must be stamped and signed by a Connecticut Professional Electrical systems, equipment and components, and heating, ventilation, air Engineer conditioning and plumbing appliances, plumbing fixtures, duct systems, and LVL's—engineering data required other service equipment shall be located at or above the design flood elevation. I-joists—engineering data required Valley rafter—engineering data required . ELECTRICAL INFORMATION Collar tie size,spacing&location not identified or insufficient Plans required showing panel locations,GFCI,switches,lights and receptacle Roof trusses — Engineering data (signed and sealed by a Connecticut locations Professional Engineer) must be submitted and approved by the Building Panel location not identified ' Department prior to installation Receptacle locations not identified or insufficient Roof truss data must be designed to ASCE 7-02 GFCI receptacle locations not identified or insufficient Ridge beam supports not identified or insufficient Lights and switches not identified or insufficient Hip/valley beam supports not identified or insufficient X Smoke alarms not identified or insufficient Rafter to beam connection detail not provided or insufficient CO detector(s)not identified or insufficient DECKS I PORCHES Electrical load calculations required Whirlpool tub/hydromessage tub disconnect location not identified Construction documents required Dimensions required MECHANICAL INFORMATION Framing direction not indicated Plans required showing equipment locations,ductwork,etc. Beam span&size not provided or insufficient Dryer vent routing not identified or insufficient Joist span,size&spacing not provided Heating,ventilation and air conditioning equipment locations not identified Joist's over-spanned Heat loss/gain calculations required to be submitted Beam over-spanned Heat loss/gain calculations do not match the information on the construction Ledger—show attachment and flashing detail documents Post size or spacing not indicatedCombustion air calculations required Height of deck above adjacent finished grade not provided Winter design temperature is 7°F Connections not identified or insufficient Plans do not match site plan FUEL GAS INFORMATION CHIMNEYS&FIREPLACES LP-Gas tank size and location not identified on the plans Trench detail not provided or insufficient Indicate clearance of masonry to combustible framing materials and clearance Piping diagram not submitted or insufficient from fireplace opening to finished trim Data for mechanical flue sizing not identified or insufficient PLUMBING SYSTEM INFORMATION Exterior combustion air source not identified No plans submitted or insufficient information Manufactures sizes Building trap location not identified(inside or outside) data and installation instructions for metal fireplaces and/or Sewer location not identified Dstove required Domestic water location not identified Dimension height of chimney above the roof Manufacturers data for whirlpools,comer tubs&large tubs required Water heater size,type,and location to be submitted Comments: ! 9 5g- nf2-/DT`r A fel-I C/�crvw. 1 .' 12-0-c2_vI R- " 052-- 0L 11 -i'fl /CAL 2 yoC.J /S �PACLr' ?o PB- )/2 A1'I?7 t 12-cv10 4 " /NP--o Permit application reviewed by: j 0" ....er. Vernon D.Vesey II �'r /ee7ph J.Summers David M.Jensen wised'Fe6ruety 6,2006 Town of Montville ► Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 RESIDENTIAL PERMIT APPLICATION FORM Permit No.: ela S—Z'o4 Type of Work Occupancy Type Permit Type ❑New Construction Da. Single Family VI.Building ❑Addition Two-Family El Plumbing El Alteration El Townhouse ❑ Mechanical ❑Accessory Structure ❑Electrical CRS#: Job Address: 2'I f e d' c rI 04 t--e D r. (Number) (Street) _ (Unit) Job Description: 2 Z I N, e 1 i $ 1Z e A / Se vh eit f S e e Owner: RO e 5 �(n Au iL1 c tom_ -e QuLb uci S Address: r (LA Nc N /4 L_I_ IZ ;) City: e jTOO State: C l Zip Code: CD3 Telephone: g( O )- Contractor: cD W DBA: Address: City: State: Zip Code: Telephone: License Type: License No.: Expiration Date: I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. ❑ By checking this box, I will follow the requirements of the 2005 NEC as the alternative compliance per section E3301.2.1 of the Residential Code, instead of the electrical requirements in chapters 33 through 42 of the Residential Code. Owner/Agent Signature: C7 CA-t-4..1 Date: g � 0 6 Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: Mechanical Fee: Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: Total Fee: 9?evised Decem6er31,2005 Town of Montville Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 CONSTRUCTION PERMIT APPROVAL 211 P€ ct4uA4e Property Address r z )(ZZ N�Lv ,L�v�N� /q/CP rg //t-/ 6,41-s-eM-eAi t Job Description The applicant is responsible for obtaining all of the required approvals checked off on this form. No building permit will be issued until all of the required signatures have been obtained. Required Department Permit Issuance Approval Approval Tax Collector (11:43:c-t.t- Comments: WPCA, Administrative cj /LI Id L Comments: ❑ WPCA, Operations Comments: Planning &Zoning . i')6b Signature/ date Comments: ,krd( OMNI ❑ Health Department Signature/date Comments: ❑ Department of Public Works Comments: ❑ State Dept. of Transportation Signature/date Comments: Fire Marshal Signature/date Comments: S‘ 4 CeAr \ (AVit- I4vuediAugust 5,2005 1 . k . : .,. . ._ . ,_ .,.„ r— o-- 01 ' _ ^ (N' e C 3 2? .7 IiyI 4 11 N y ,tr l AZ 0 \it) -I 4 a o 2 d d \�41 a- _ Q <xi i'3 / \I 14 ' -3 3 , • . o � ft Q i4` -r Co .t - Q __________}.‘‘-- Q -§ o— T et il d V) 0 .1 f T Lu N Q ici( t%barri q — Ni 2 i. J� w _N Lt 1A z X 1---:4 i