HomeMy WebLinkAboutSFR Heating and A/C Town of Montville
Building Department
Phone: 848-7166 310 Norwich New London Tpke Fax: 848-7231
Building /Trades Permit
Permit Number H2000-108 Permit Date 8/25/00 Permit Type Heating Permit Code R5
Job Street# 6 Job Location Partridge Hollow Map/Block-Lot 028/005-080
Job Description heating with A/C for new house
Owner D'amato Bros. Mailing Address P.O. Box 3063
City Milford State Ct. Zip 06460 Telephone 203-874-5992
Contractor Viglione H &C *Mailing Address 259 Commerce Street
*City East Haven *State Ct. *Zip 06512 _ *Telephone 203-467-8388
Lic/Reg Number 302380 Lic/Reg Type S1 Expiration Date 8/31/00
Use Group R4 Size Type Construction 5B
Building Value $0.00 Building Fee $0.00
Plumbing Value $0.00 Plumbing Fee $0.00
Heating Value $0.00 Heating Fee $0.00
Electrical Value Electrical Fee $0.00
A/C Value $0.00 A/C Fee $0.00
Other Value $0.00 Other Fee $0.00
Total Values $0.00 State Ed Fee $0.00
paid on building permit C/O Fee $0.00
Plan Review Fee $0.00
Total Fees $0.00
Building Official's Signatur % / r/
Date /Z'`� /oe
Required Inspection
❑ Footings-Prior to pouring concrete le Rough Heating and Air Conditioning
❑ Footing Drains/Waterproofing - Prior to backfill ❑ Chimney -One flue above thimble
❑ Framing ❑ Fireplace-Throat
[J Rough Electrical
❑ Fireplace- Final
❑ Electrical Service ❑ Firestopping/Draftstopping
❑ Rough Plumbing - Leak test required ❑ Insulation
❑ Pool Bonding and Electric
® Final Inspection for Certificate of Occupancy -PRIOR to Use or Occupancy
Town Of Montville
Building Department
310 Norwich-New London Tpke.
Uncasville, Ct. 06382
Tel. 848-7166 Fax 848-7231
Application for Building or Trades Permit
Owner Di A( cit C OThe_(S Mailing Address 710 . 3O) 3
City r t\"fad State CrZip CO-1-6j Tel.o -V -
Job Location (9Rari-C7l63 , 101100.. Map/Block-Lot 0'../'53`10 Z 6—- 0 et)
Contractor 49`1QCEE 4eochn9Y (0661 ailing Address o�.R Comme c.e. Si- .
City &io + a'f€f 1 State Cr Zip Cto5Q Tel. o)Q -1-6-1 -g
Type of Permit
❑New Single Family ❑ New Two Family ❑ Addition ❑ Commercial ❑ Industrial
[A❑ Iteration [ Garage ❑ C rport ❑ Shed ❑ Roofmg
ir Conditioning nPlumbing [ eating ❑ Electrical ❑ Gas
❑ Retaining Wall n Deck ❑ Pool ❑ Patio ❑ Porch
❑ Demolition ❑ Siding ❑ Windows ❑ Fireplace ❑ Chimney
JobDescription/Materials 'i'S 01k 03: aYl 66 r hEtJti u)rk-h al r C3no:aionllC3
Size Type of Heat (, x:tffrn a.-1 ( Use CSC)e t I:1 1
I hereby certify that the proposed work will conform to the Basic Building Code and all other codes as adopted
by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized
by the owner in fee and that I am authorized to make application for a permit for such work as described above.
New Home Construction Contractors: Have you entered into a contract with the consumer for the proposed
work ? ❑ Yes ❑ No -
Owner/Agent Signature /j/ Date 7// I' /DOO
Contractors License/Registration Type &Number 3 t 30a38::s Exp.Date e / / / a
Construction Value Fee
Building $ $
Plumbing $ $
Heating $ $
ql
Electrical $ $
Air Conditioning $ $ /\�
Other $ $ fi
Certificate of Occupancy $ if
Plan Review Fee $ �-
State Education Fee $
Total $ $
VIGLIONE HTG & CLG, INC. PROJECT: STERLING 2288 SQ FT
259 COMMERCE DRIVE CLIENT: DAMATO BROS
EAST HAVEN, CT 06512 DATE : 05/17/99
RESIDENTIAL/LIGHT COMMERCIAL HVAC LOADS DESIGNER: STEVE VIGLIONE
CLIENT INFORMATION:
NAME: DAMATO BROS
ADDRESS : SANDPIPER LANE
CITY, STATE : MONTVILLE CONN
TOTAL BUILDING LOADS :
BLDG. LOAD AREA SEN. LAT. + SEN. = TOTAL
DESCRIPTIONS QUAN LOSS GAIN GAIN GAIN
3-C WINDOW DBL PANE CLR GLS METL FR 210 12 , 180 0 4 , 440 4, 440
12-I WALL R-19 +1/2 "ASPHLT BRD (R-1 . 3) 2 , 234 9, 829 0 2 , 902 2 , 902
11-C DOOR METAL POLYSTYRENE CORE 84 3 , 158 0 932 932
16-G CEILING R-30 INSULATION 1, 232 3 , 252 0 1, 789 1, 789
19-A FLOOR/ENCL CRAWL HARDWD NO INS 2 , 288 28, 554 . 0 0 0
SUBTOTALS FOR STRUCTURE: 6, 048 56, 973 0 10, 063 10 , 063
PEOPLE 8 0 1, 840 2 , 400 4, 240
APPLIANCES 0 0 0 1, 200 1, 200
DUCTWORK 0 7 , 357 0 787 787
INFILTRATION W. CFM: 188 . 6 S . CFM: 94 . 3 0 16, 596 2 , 629 2 , 074 4, 703
VENTILATION W.CFM: 70 . 7 S . CFM: 70 . 7 0 6 , 223 1, 972 1, 556 3 , 528
SENSIBLE GAIN TOTAL 18 , 080
TEMP . SWING MULTIPLIER X 1 . 00
BUILDING LOAD TOTALS 87, 149 6 , 441 18 , 080 24, 521
SUPPLY CFM AT 80 . 10 DEG HTG DT: 919 CFM PER SQUARE FOOT: 0 . 520
SQUARE FT. OF ROOM AREA: 1, 768 SQUARE FOOT PER TON: 865 . 218
TOTAL HEATING REQUIRED WITH OUTSIDE AIR: 87 . 149 MBH
TOTAL COOLING REQUIRED WITH OUTSIDE AIR: 2 . 043 TONS
CALCULATIONS ARE BASED ON 7TH EDITION OF ACCA MANUAL J.
ALL COMPUTED RESULTS ARE ESTIMATES AS BUILDING USE AND WEATHER MAY VARY.
BE SURE TO SELECT A UNIT THAT MEETS BOTH SENSIBLE AND LATENT LOADS .
******** RESIDENTIAL AND LIGHT COMMERCIAL HVAC LOADS BY ELITE SOFTWARE *******
VIGLIONE HTG & CLG, INC. EAST HAVEN, CT 06512
STERLING 2288 SQ FT 05/17/99 PAGE 2
************************* ZONE # 1 ROOM LORD SUMMARY *************************
RM ROOM AREA HEATING COOLING
NO . DESCRIPTION (SF) BTUH o TOT CFM BTUH $ TOT CFM
1 . WHOLE FIRST FL 816 38 , 262 47 . 3 435 7 , 944 48 . 1 442
2 . WHOLE SECOND FL+++ 952 42 , 664 52 . 7 484 8, 580 51 . 9 477
ZONE SUBTOTAL 1, 768 80 , 926 100 . 0 919 16 , 524 100 . 0 919
VENTILATION 6, 223 1, 556
LATENT GAIN 6 , 441
ZONE TOTALS 87, 149 24 , 521 2 . 043 TONS