Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Furnace Replacement and Two 120lb Avove Ground Tanks
TOWN OF MONTVILLE Building Department 310 NORWICH-NEW LONDON TURNPIKE UNCASVILLE, CT 06382-2599 TEL. (860) 848-3030 X382 FAX. (860) 848-7231 MECHANICAL PERMIT Permit Number: M2017-0129 Date: 31-Jul-17 Map/Lot: 038/061-T11 Owner ID: 4361000 Project Location: 15 MEETINGHOUSE LANE Unit: 13 Job Description: Replace Conversion Gas Furnace&Set Two 120 lb Above Ground LP Tanks Owner Nam Donna M.Yarbrough Tenant Name N/A Careof: 15 Meetinghouse Ln Lot 13 Oakdale C'T 06370- Telephone: (860)848-6956 Applicant Name Richard Johnson Telephone: (203)974-6440 DBA: DDLC Energy Lic/Reg Type S1 Lic/Reg N 303006 240A Sargent Drive Exp Date: 31-Aug-17 New Haven CT 06511- Construction Value Permit Fees Construction Information Building Value: $0.00 Building Fee: $0.00 Use Group: IRC Plumbing Value: $0.00 Plumbing Fee: $0.00 Code: 2016 State Building Code Mechanical Valu $4,950.00 Mechanical Fe $60.00 Electrical Value: $0.00 Electrical Fee: $0.00 Construction Type IRC Total Value: $4,950.00 Penalty Fee: $0.00 Permit Code: R5 C of 0 Fee: $0.00 Comment Plan Review Fe $0.00 State Ed Fee: $1.29 Total Fee Paid: $61.29 It shall be the owners repsonsibility to schedule the following inspections a minimum of 2 business days in advance: Field set of approved construction documents shall be available onsite during all inspections. BUILDING PERMIT INSPECTIONS PLUMBING,MECHANICAL, ELECTRICAL PERMIT INSPECTIONS ❑ Footing-Prior to pouring concrete ❑ R Plumbing and leak test ❑ Deck Piers ❑ R Electrical ❑ Backfill-Footing drains and waterproofing ❑ Elec Trench-with conduit installed ❑ Concrete Slab-Prior to pouring concrete ❑ Pool Bonding ❑ Anchor Bolts-with sill plate and prior to floor frami ❑ Electrical Service CRS No: 0 ❑ Framing ❑ R HVAC ❑ Masonry Fireplace Throat or Chimney Thimble ❑d Gas Piping and leak test ❑ Fireblocking Draftstopping INSPECTION REQUIRED UPON COMPLETION ❑ Insulation ❑� Certificate of App .val et' a - . occupancy Building Official's Approval: Town or iviontviule Building Department 310 Norwich-New London Tpke. Tel. 860-848-3030, Ext 382 Uncasville, CT 06382 Fax. 860-848-7231 PERMIT APPLICATION FORM Permit No.: 013C-4/-6139 Type of Work Occupancy Classification Construction Type Permit Type ❑ New Construction ❑A-1 0 B ❑ H-1 ❑1-1 0 R-1 ❑S-1 ❑Type IA El Type IIIB ❑ Building ❑Addition ❑A-2 ❑B,Medical ❑ H-2 ❑ I-2 ❑ R-2 ❑S-2 ❑Type IB ❑Type IV ❑ Plumbing ❑Alteration ❑A-3 ❑E ❑ H-3 ❑1-3 ❑ R-3 ❑ U ❑Type IIA ❑Type VA ❑ Mechanical ❑Change of Use 0 A-4 0 F-1 ❑H-4 ❑1-4 ❑ R-4 ❑ Mixed ❑Type IIB ❑Type VB ❑ Electrical ❑A-5 ❑FF-2 ❑M ❑Type IIIA CRS#: Property Address: 15- ' I I n5 lAOV.0 (Ark #13 Number) (Street) I f (Unit) Job Description: � r,vQ,rs,o, AS- •Vff\hCJ (2)L.1 Ste` ( I Q►- � L` �lni'C'S Owner: 0Qr\1\ rn \.nrioCCVD\eN Tenant: Address: M".71 n RAM-U ' _Address: City/State/Zip: 0 rnk&VA CI— 01810 / City/State/Zip: o - bq5 6 Telephone( ) Telephone( ) Applicant: 2IG��f� Jc��SC DBA: Addre : '2 - o Skr?yr, c� C L City. l�J Q AA�`Ie Q_ State:LA Zip Code:Q6 t\ Telephone( �3 ) � - V6((�`Q Contractors - Complete the Following: (� 11 License/Registration Type: ��� License/Registration No.:C �`�`'�SExpiration Date: 3/5`l '1 I hereby certify that the proposed work will conform to the State Building Code and all other codes as adopted by the State of Connecticut and the Town of Montville and further attest that the proposed work is authorized by the owner in fee and that I am authorized to make application for a permit for such work as described above. fi Owner(12 t Signature Date: 0 7 o> Construction Value Permit Fees Building Value: Building Fee: Plumbing Value: Plumbing Fee: Mechanical Value: ``1 7 C. Mechanical Fee: QC) — Electrical Value: Electrical Fee: Total Value: Penalty Fee: C of 0 Fee: Plan Review Fee: State Ed Fee: l - <G 5 • Total Fee: Le 1 _3q Revise&August 23,2037 Town of Montville Building Department File Receipt Date: 28-Jul-17 ReceiptNo: 12503 Received From: Connecticut Permit Services Job Address: 15 Meetinghouse Lane #13 Town Fees Collected State of Connecticut Fees Collected Bldg Cash: 50.00 State Cash: 50.00 Bldg Check: 561.29 State Check: $1.29 Bldg Credit: 50.00 State Credit: 50.00 Fire Cash: 50.00 Fire Check: 50.00 Fire Credit: 80.00 Construction Value: $4.950.00 Demolition Value: 10.00 CheckNo: 25291 Received By: Carmen Kneeland Address: 15 Meetinghouse Lane#13 ITEM QTY $/UNIT TOTAL Building Plumbing Mechanical Electrical BUILDING AREA Basement,Finished SF $ 41.96 $ - $ - Interior Renovations SF $ 36.09 $ - $ - $ - AMENITIES Kitchen EA $ - $ - S - Full Bathroom EA $ - $ - Half-Bathroom EA $ - $ - GARAGE Detached SF $ 71.53 $ - $ - MECHANICAL Warm-Air n Y/N $ - Hot Water n Y/N $ - Electric n Y/N $ - Air Conditioning n Y/N $ - ELECTRICAL SERVICE Upgrade Amps $ - Subpanel EA $ 699.00 $ - Gen Set EA $ 3,850.00 $ - SOLID FUEL BURNING APPLIANCES Prefab Metal Fireplace EA $ 6,497.70 $ - Masonry w/lfireplace EA $ 7,096.65 $ - Masonry w/2 fireplaces EA $ 11,095.70 $ - Wood Stove,free standing EA $ 2,692.25 $ - Wood stove insert EA $ 1,859.77 $ - DECKS,PORCHES,SUNROOMS Deck SF $ 44.07 $ - Porch SF $ 149.38 $ - Sunroom SF $ 176.90 $ - $ - POOLS&HOT TUBS Hot Tub EA $ 8,016.25 $ - $ - Inground Pool EA $ 31,550.00 $ - $ - Above Ground Round EA $ 6,299.46 $ - $ - Above Ground Oval EA $ 7,019.75 $ - $ - Pool Heater EA $ 8,984.25 $ - $ - Inflatable Type Pool EA $ 1,200.00 $ - $ - SHEDS w/o electrical SF $ 25.55 $ - w/electrical SF $ 26.85 $ - $ - RENOVATIONS Roofing,Overlay SF $ 3.50 $ - Roofing,Strip&reroof SF $ 4.50 $ - Roof Sheathing SF $ 1.51 $ - Siding SF $ 6.75 $ - Windows EA $ 550.00 $ - Skylights EA $ 1,051.10 $ - Doors,Exterior EA $ 601.50 $ - Oil Tank,275 Gallon EA $ - Oil Tank.550 Gallon EA $ - MISCELLANEOUS CALCULATIONS $ 4,950.00 Solar Install n TOTALS $ - $ - $ 4,950.00 $ - PERMIT FEE CALCULATIONS Construction Value Fee Building $ - $ - Plumbing y $ - $ - Mechanical y $ 4,950.00 $ 60.00 Electrical y $ - $ - Plan Review Fee y $ - Certificate of Occupancy Fee $ - Plan Review Fee $ - State Education Fee $ 1.29 TOTALS $ 4,950.00 $ 61.29 Figures are based on the 2006 RS Means Residential Cost Data J1I4JDDLC 36 Brownstone Avenue, Portland, CT 06480 D * ENERGY (800) 815-1128 Fax: (860) 342-4455 Date 0701411 To ATTN: Town Building Inspector Re PERMIT AUTHORIZATION LETTER Dear Sirs: In accordance with Connecticut Statute 20-338B, this letter serves as written authorization and notification that Connecticut Permit Services, Inc. Employee listed below have the authority to represent us in the procurement of permits and pertinent documentation on our behalf as detailed below. Project Start Date fV Project End Date Project Type: SE., 0-) Imo h\ NG% lT,(\x- ,v4.5 I TN.tx- aS �,nr�� Location: 1-4\1\c, \G\i.bm.<1`4, V'c M ,E-�(-0,`c-\c‘fw\ 1*1T NyV- .c.\et, Y— (I o Authorized Agent Connecticut Permit Services, Inc. Service Agent name MetttALA ge443C{, Very truly Yours, Licensee Signature 1111111WT__ Printed Name Richard Johnson License Number 51-303006 Notary Public Printed Name ALA.\\00 ,tti\--\ My Commission Expires l\i 111Q Notary Public Signature UKiAou tt4381 ` Heather M. Dutton NOTARY PUBLIC My Commission Expires January 31,201( • . aS • ^� i �� � ' i {`D ' ' 1I lJ1a� il. i{ 1 � �• ► 1 ."•d — e lig ® . ✓r•. 4• E) U 0 . • • alfa W H j••'� :; ,„•,,, ‘,.. 9_4 . ...-,1 li!,-,40,g ._(_, , .ti fo.,,,:, _ H • ..: /et :-_,.2:::... OW �C1 c9 4 LC) C!) P t--{ �!,?S. c7r• u / cI} -f f E Z o �' 'i. r . _ ,,J. • 4 0 U o N___.:....\4 4-1 diDi %� H o � g • H -n•-•:-.:•••.. . • ,,t , .,-, }--c 4.4 ;--• )4 1 )4& . . -*q> p-( 0 w It 1 •, -4..-:, . co ! gAr - ,•,i... 0 t--- .&,i,-$2:4 /.V•j v I�YC> . 1 per, Hr-t W �,—{t I f, .• i p Cr) • �'-s -,.., -p--:••-•1• ( s` `--c cz-., ,,H ‹..___‘., , 14__��, .4A\ r: o W • •�+ -Yom= 4 . 0 (4_, x 6„. --f: i .,r ,,,‹-±,-:% c.,_, • ,.5--!>;310'...NIP]W713-''.1 1%,, . N 4t.• 4.•.•• '; a.r d.17.'a.:,q "1,,;(4.; 2,Ay 'a.,..•.",.4.-nivp.,:zi.v.; �b �`` :U. v.u_`;� �' .. ly _ L �,'s• ,� •, _, cr� ti . ACO o® CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DD/YYYY)10/26/2016 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: PG Genatt Group LLC PHONE 3333 NEW HYDE PARK RD (Arc.No.Exu:516 869 8788 (a/c,Ne):1 516 470 0338 SUITE 409 A ADDDREDRE SS: NEW HYDE PARK NY 11042 INSURER(S)AFFORDING COVERAGE NAIC F INSURER A:First Mercury insurance Compan 10657 INSURED INSURER B Transportation Insurance Co. 20494 HOP ENERGY DBA INSURER C:VaIIey Forge 20508 KAUFMAN FUEL CO. 836 FAIRFIELD AVE INSURER D:Travelers Property C,a,Slaalty Co,of BRIDGEPORT CT 06604 INSURER E: -,.its •I I .I - 0 I 11.,I 19437 INSURER F: COVERAGES CERTIFICATE NUMBER:130679040 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSR WVD POLICY NUMBER (MM/DD/YYYY) (MM/DD/YYYY) LIMITS A GENERAL LIABILITY MACGL000001890605 10/27/2016 10/27/2017 EACH OCCURRENCE $1,000,000 X COMMERCIAL GENERAL LIABILITY DAMAGE TO RENTED PREMISES(Ea occurrence) 550,000 CLAIMS-MADE X OCCUR MED EXP(Any one person) 5 X SIR$100,000 PERSONAL A.ADV INJURY $1,000,000 GENERAL AGGREGATE $2,000,000 • GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $2,000,000 —I POLICY PRO- JECT LOC $ B AUTOMOBILE LIABILITY BUA2098344188 10/27/2016 10/27/2017 COMBINED SINGLE LIMIT (Ea accident) $1,000,000 X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED AUTOS _ AUTOS BODILY INJURY(Per accident) $ HIRED AUTOS AU OSWNED PROPERTY DAMAGE $ (Per accident) $ E X UMBRELLA LIAB X OCCUR 015375083 10/27/2016 10/27/2017 EACH OCCURRENCE _ $4,000,000 EXCESS LIAB CLAIMS-MADE AGGREGATE $4,000,000 DED X RETENTION$10,000 $ C WORKERS COMPENSATION WC2098344093 10/27/2016 10/27/2017 X WC STATU- OTH- p AND EMPLOYERS'LIABILITY Y/N 7PJUB5B70389516 10/27/2016 10/27/2017 TORY I IMITS FR ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $1,000,000 OFFICER/MEMBER EXCLUDED? N/A (Mandatory In NH) E.L.DISEASE-EA EMPLOYEE $1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $1,000,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Remarks Schedule,U more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Go For Services THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 240A Sargent Dr ACCORDANCE WITH THE POLICY PROVISIONS. P.O. Box 411 New Haven CT 06511 AUTHORIZED REPRESENTATIVE 1 • ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD Town of Montville Building Department CONSTRUCTION PERMIT APPROVAL Ric 3 Property Address .R12/0.Cnt,e- V-UrrN C`(-U 7eA- (2--) /VC _ Job De cription Required Department Permit Issuance Approval Approval Tax Collector 7*--2 Signature/date Comments: Fire Marshal ?l,2 Signature/date Comments: ❑ Planning &Zoning Required for all permits except Signature/date Plumbing,Electrical,Mechanical. Roofing,Siding,Windows&Doors ❑ Health Department Required for properties with private septic or well Signature/date Comments: ❑ WPCA, Administrative }- Required for properties on sewer Signature/date Comments: ❑ WPCA, Operations When Required by WPCA Signature/date Comments: ❑ Department of Public Works Required when project includes driveway work or certain drainage requirements Signature/date Comments: ❑ Montville Police Department Required for all permits EXCEPT one and two family residential Signature/date Comments: ❑ Copy of State Dept. of Transportation Certificate Required for Structures over 100,000 sq.ft.or with more than 200 parking spaces-Official copy of STC Certificate of Operation required—per CGS 14-311 Signature/date Building Department Final Inspection Revised March23,2015 t DDLC Energy HOp 860-271-2020 111 a DDI 4 C 410 Bank Street Fax; 860-271-2050 New London, CT 06320 DDENERGY CT-S1-303006 and RI PM 3386 HOD 40000385 JOB NO. 30- OIL ACCT.NO. PT.7OOrp INT.ACCT.NO. Applicant Co-Applicant Name DONNA YARBROUGH Address Address 15 MEETING HOUSE LANE/LOT 13 City,State,Zip City,State,Zip OAKDALE,CT 06370 Email Email Phone# Work Phone# Cell Phone# Phone# Work Phone# Cell Phone# Aho-eye= o'9f ' Payment Options; Credit Card Issuer U American Express U Discover ❑Master Card ❑VISA D Personal Check or Money Order 0 Boiler Qty_ Model 5 _________ 0 Oil Tank Qty—Model# Furnace/Air Handler Qty_Modei 5 MILLER ____ ❑Humidifier Qty_Modei# _ 0 Condenser/Heat Pump Qty___Model# _ 0 Chimney Liner Qty_Model it o Water Heater/Indirect Qty_ Model 5 ________ 0 Generator Qty Model# ❑.AIC Coil Qty_Modei ft _ 0 Maintenance Plan Exp. _ Scope of work:(attach additional description and/or drawings if necessary) Check box if additional page(s)were used to describe work. 0#pg. REPLACE EXISTING KEROSENE FURNACE WITH A NEW PROPANE FIRED MILLER FURNACE.ATTACH TO EXISTING DUCT SYSTEM.INSTALL NEW BAS FOR FURNACE INSTALL BLANK OFF DAMPER FOR EXISTING AC SYSTEM.INSTALL NEW VENT KIT AS NEEDED.RECONNECT ELECTRICAL.TO NEW FURNACE.SET 2-120 GALLON PROPANE TANKS WHERE SMALLER PROPANE TANK IS CURRENTLY SET. INSTALL REGULATOR AND GAS LINE TO NEW FURNACE.INSTALL TEE IN GAS UNE TO TIE INTO EXISTING GAS RANGE.START AND TEST HEATING SYSTEM.DISPOSE Or OLD FURNACE.JOB INCLUDES ALL MATERIAL TAXES.LABOR AND PERMIT FEE. installation may include necessary local fees,licenses and permits relative to this proposal. THIS QUOTE IS VALID FOR THIRTY DAYS FROM: Replacement of the heating unit will be performed after Asbestos has been removed,at Buyer's expense,by a licensed Asbestos removal contractor,and disposed of in accordance with 1.Installation Total Cost S 4,950 government regulations.Price does not include Asbestos removal__- ____(initials) 2.Disposal Fee _ 49.00 Any limitations of existing duct work system is the responsibility of the owner _(initials) 4,950 3.Total Installation Cost $ . For valuable consideration received.'Ave the undersigned do hereby absolutely and unconditionally 2,475 guarantee,as an individual's),payment of any indebtedness incurred by virtue of any and all credit 4.Down payment $ ---- extended in accordance with the within agreement and all of its terms and conditions.The undersigned consents to HOP Energy obtaining a Consumer Credit Report on Applicant and/or co-applicant for the pur- pose of evaluating the credit worthiness of applicant and/or co-applicant, in connection with an 5.Amount Financed $ 47 application of credit. The amount of credit provided to you on your behalf NOTICE TO BUYER: 1.Do not sign this contract before you read it or if it contains any 6.Amount of Monthly Payment $103.12_ blank space. 2. You are entitled to a completely filled-in copy of the contract when you sign it. 3. Under the law,you have the following rights,among others: (a)to pay off in ad- 7.Number of Monthly Payments $24 -- vance the full amount due and obtain a partial refund of any unearned finance charge;(b) to redeem the property if repossessed for a default;(c)to require,under certain conditions, g Total of Payments $4,950 a resale of the property if repossessed.YOU,THE BUYER, MAY CANCEL The amount you will have paid when you have THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF made all scheduled payments Each Payment Due on(date) 30 days after billing THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. SEE THE ATTACHED NOTICE OF Payment Schedule Starting on 30 days after billing CANCELLATION FORM FOR AN EXPLANATION OF THIS o % 9.Annual Percentage Rate .-__ RIGHT. You acknowledge that Seller has delivered or mailed to you an executed copy of as a yearly rate this contract. 10. Finance Charge $0 _. Uwe hereby accept the terms and conditions of the proposal as set for the above and on the The Dollar amount the credit will cost you 4,950 reverse side of the sheet,all of wi/we have read and agree to be bound thereby. 11.Total Sale Price $ -- ----- 7/I3117 The total price of your purchase on credit, Applicant DONNA YARBROUGH ' t nDate including your down payment Co-Applicant __._ Date 7113117 -�� ({� 7113/17 Print Name Applicant .f J 6 T1 C\ r Jr LC' Date /13117 Sales Representative JEFFREY \a..\,k Date Co-Applicant. Date 7n317 •_ Branch ManagerDate_____ www.DDLCEnergy.com C57-306-10 HOP Energy SLAM Lead Information Name Donna Yarbrough Interested In Propane-Equipment Delivery 15 Meeting House Ln Lot 13 Lead Source Existing Customer Address Oakdale CT 06370 Mailer Response Sales Status Credit Approved Billing PO Box 46 Outside Sales Rep Address Oakdale CT 063700046 Inside Sales Rep Branch DDLC Energy Email Date Created 07/11/2017 Phones Home: 8608928124 Created By Ibandison Mobile : Date Updated 07/16/2017 Updated By jgrieco Move Out Date Existing Acct Y 5853008 Attorney Realtor LandLord HD Prospect# HD Lead Gen Employee Ref HD Store# 0 Svc Tech Ref 0 Promotions Type $Value Account/Credit Applications CreditStatus DateApproved Approval Conditions Energy Acct Budget? Budget Start Approved 07/16/2017 N 01/01/1900 Comments Created By Ibandison Date Created 7111117 Updated By Ibandison Date Updated 7/11/17 An appt has been schd for 07/12/17 @ 2pm, wants to replace propane unit plus tank Created By Ibandison Date Created 7114/17 Updated By Ibandison Date Updated 7/14/17 Print for payment ' Furnace &Air Conditioning Survey Equipment Specialist JEFF GRIECO Branch DDLC Customer's Name DONNA YARBROUGH Date 7/15/2017 Customer's E-mail Install Address 15 MEETING HOUSE LANE#13 Customer Contact Numbers City/Town OAKDALE CT Zip 06370 Home# Municipality/Township PO-ere-6-94.7 Billing Address SAME Cell# City/Town Zip Work# Account# CV)«hotr I Existing Equipment Lo-Boy Hi-Boy Counter Flow X Horizontal #of Zones 1 Make MILLER Model Front Flue X Rear Flue Humidifer EAC A/C Size of Smoke Pipe 4 Size of Warm Air Plenum: Length Width Height Size of Cold Air Plenum: Length Width Height Size of Main Hot Air Supply Trunk x Furnace Height Distance Between Plenums Main Cold Air Supply Trunk x Ductwork type Steel Size of Smoke Pipe Size of Chimney Thimble A/C Chimney Location Central Chimney Height Power Vented Chimney Type Direct Vent Metal Pre-Fab X How Domestic Hot Water is Provided WATER HEATER I New Equipment Sold I New Unit MILLER Front Flue X Rear Flue New Burner LP #of registers Belt Driver Blower Direct Drive Blower X Fresh Air Kit Number of Zones 1 Size of Dampers Control Panel A/C NO Humidifier EAC Other IAccess to building Entry in through house If other Size Floor Covering Required YES Basement Height Area Clear YES Basement Floor Type If other #of steps Does equipment need to be cut to be removed Special Instructions MOBILE HOME UNIT. REPLACE KEROSENE UNIT WITH LG GAS UNIT SET 2 120 GALLON TANKS.RUN GAS LINE. (S-4-7.P Lcery rtdkc. Ac\tvtvSci /CiAVetk — PVelr . Date Job Scheduled NOT Lead Source(Tech name, Lowes, Date proposal signed 7/13/2017 etc.) EXISTING CUSTOMER Cost Summary Sheet Major Materials Needed Equipment Description Part# Part Cost Qty Total FURNACE 1120 $1,120.00 $0.00 $0.00 $1,120.00 Minor Materials Needed Equipment Description Part# Part Cost Qty Total Minor Materials Needed 500 $500.00 $0.00 $0.00 $500.00 Miscellaneous Materials Needed Equipment Description Part# Part Cost Qty Total $0.00 $0.00 $0.00 $0.00 Labor Required Sub Contractor Rate(In house Labor hours Total to pay to sub Total Or In House $48/hr) Sub 800 $800.00 In House 6 $48 $288.00 $0.00 $0.00 $1,088.00 Cost Summary Sales Estimate Actual Variance %Variance Sales Price prior to allowances/rebates incl $49 Disposal Fee $4,950.00 Service Contract Allowance Other Credits/Rebates Net Sale Price $4,950.00 Major Materials $1,120.00 Minor Materials $500.00 Miscellaneous Materials Labor(In House/sub) $1,088.00 Permits $100.00 Taxes $102.00 Total Cost $2,708.00 Mark-up used 0.55 Gross Profit $1,648.00 GP% 33.29% Commission% 12.00% Other Information .s D v THE NITE (o Ri) QUOTE Cirtour Tire Granite Group :R 44 sof 4O n9 ouR 75 Jefferson Avenue New London,CT 06320 Order# 10109722-00 wwtv.thegranitegraup.com (860)442-4348 Page# 1 www.uitimatebathstore.com Ship Point The Granite Group BR 44 Via PICK UP Terms ar 2410thN30 Bill To: 24646 Ship To Entered 07112:17 HOP ENERGY LLC DBA DDLC ENERGY CT JOBS ONLY Promised 07/12/17 CIO VALLEY OIL HOP ENERGY LLC DBA DDLC ENERGY 36 BROWNSTONE AVE 410 BANK ST PORTLAND,CT 06480 NEW LONDON,CT 06430 Instructions Taken By jps Sales in jps Sales out JPP1 Placed by Customer PK) DONNA PO#REQUIRED ice# Product Qty Qty Qty Qty Unit Price Amount And Descnlation Ordered 8/0 Shipped U/M Price Unit (Net) I MILCMF280PG 1 1 EACH 1119.67 EACH 1119.67 *904515 CMF 80 PG FURNACE(MIT 903097B) Interchange Prod:CNIF280PG * *The CMF28OPG is currently"NOT AVAILABLE"* *Use substitute Cl4iF950 7 2PG(921327)and you must also *use M1L921683 CMF95JM7Replacement vent kit * Serialized product. 2 M1L903101 1 1 EACH 9.82 EACH 9.82 903101 80 TO 100 PG CONV KIT 3 MIL902095 1 1 EACH 65.18 EACH 65.18 902095 AUTO BASEDPR-103341000 CMF S ,1.903451 1 1 EACH 112.97 EACH 112.97 903451 M .100 UNIVERSAL BASE *****vERY IMPORTANT NOTE************************************ Because of the probability the CMF2 will be installed on a duct system that is served(or will one day be served)also by a self contained air-conditioner,it is important to include an automatic blank-off damper with every CMF2 installation. The automatic blank-off damper(902095)must be installed in an MA-100 base(903450 or 903451)underneath the CMF2 furnace before the CMF2 is placed on top of the base. There is no provision for installation of the automatic damper in a CMF2 furnace after it has been placed on the base(as was the case with the?classic CMF?). 7 M1L104060003 1 1 EACH 94.34 EACH 94.34 104060003 SRJ-2 24 ROOF JACK 5 Lines Total Qty Shipped Total 5 Line Total 1401.98 Freight 75.50 Invoice Total 1477.48 UNLESS kOTEC ELSEWHERE.THIS OUOTE IS ONLY VALD FOR 30 DAYS FROM THE ENTERED DATE THIS CONTRACT IS GOVERNED EY AND SUBJECT TO THE GRANITE GPO-UP WHOLESALERS LLGS STANDARD TERMS AND CONOlTIONS'.LOCATED AT WWW THEGRAMI TEGROUP COM?ERMSANDCCNDmONS/THE TERMS AND CONDITIONS'LOCATED AT WWW THEGP.A.N.TEGROUP COM,TERMSANGCONDITiONS'ARE HEREBY INCORPORATED BY REFERENCE INTO THIS DOCUMENT BY PURCHASING GOODS FROM THE GRANITE GROUP WHOLESALERS.LW,YOU ACKNOWLEDGE YOU HAVE READ THE TERMS AND CONDITIONS'AND AGREE TO AND INTEND TO LIE BOUND BY THE'TERMS AND CONOITKANE LOCATED AT WWX.THEGRANITEGPOL'P.COMTERMSANDGONDITIONS.BOT,.P4RT.ES AGREE THAI THESE TERMS AND CONDITIONS'ARE SUBJECT TO CHANGE. Page 1 of 1 Customer Copy 9 Load Short Form Job: Wrl f ItSOft` Date: Jul 16,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE#13, OAKDALE, CT 06370 Design Information Htg Clg Infiltration Outside db(°F) 6 85 Method Simplified Inside db(°F) 70 75 Construction quality Average Design TD (°F) 64 10 Fireplaces 0 Daily range - M Inside humidity (%) 50 50 Moisture difference(gr/Ib) 49 32 HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 136 ft Actual air flow 762 cfm High output baseboard 700 Btuh/ft Air flow factor 0.042 cfm/Btuh Total high baseboard 97 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 ROOM NAME Area Htg load Clg load Baseboard (ft) CIgAVF (ft') (Btuh) (Btuh) Low High (cfm) WHOLE HOUSE 1500 68136 17956 136 97 762 Entire House d 1500 68136 17956 136 97 762 Other equip loads 0 0 Equip. @ 0.90 RSM 16161 Latent cooling 2144 TOTALS 1500 68136 18305 136 97 762 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2017-Ju1-16 13:23:59 Right-Suite®Universal 2017 17.0.01 RSU20117 Page 1 Z64. Projectt.rup Calc=MJ8 Front Door faces: N i * wrightsoft, Loads for Multiple Orientations Job: Date: Jul 16,2017 Entire House BY: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE#13, OAKDALE, CT 06370 Design Conditions Location: Indoor: Heating Cooling New London(Bridgeport Dd), CT, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 64 10 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(grub) 48.8 32.5 Dry bulb(°F) 6 85 Infiltration: Daily range(°F) - 20 ( M ) Wet bulb(°F) - 72 Wind speed(mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load(Btuh) 16161 19679 23673 22099 19206 24097 26780 22140 Latent Load(Btuh) 2144 2276 2502 2416 2272 2506 2662 2415 Total Load(Btuh) 18305 21955 26175 24514 21478 26603 29442 24555 Heating AVF(elm) 762 931 1114 1036 912 1133 1268 1036 Cooling AVF(elm) 762 931 1114 1036 912 1133 1268 1036 Building Orientation Cooling Load 30000 2 25000 0 CD -0 20000 0 0 _..1 F 15000 '3'0 C) is 10000 0 1- 5000 , , 0 I 1 I N NE E SE S SW W NW , i, Direction Front Door faces f [ Current Orientation: Front Door faces North i Highest Cooling Load: Front Door faces West 2. P 1 .' Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2 6 i 5 2017-Jul-16 13:23:59 i wrightsoft Right Suite®Universal 2017 17.0.01 RSU20117 i Page 1 1: AE—Ck. Project-Li-up Cale=MJ8 Front Door faces: N 1 1 1 I. • 4 wrightsoft Building Analysis Job: Date: Jul 16,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Pro'ect Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE #13, OAKDALE, CT 06370 Design Conditions Location: Indoor: Heating Cooling New London (Bridgeport Dd), CT, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 64 10 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 48.8 32.5 Dry bulb(°F) 6 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heatin. Component Btuh/ft2 Btuh % of load Walls 6.2 8306 12.2 Glazing 36.5 4378 6.4 w.\ ,...... Doors 38.4 1613 2.4 Ceilings 3.1 4704 6.9 Floors 24.6 36960 54.2 Infiltration 4.2 6334 9.3 Ducts 5842 8.6 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 68136 100.0 Coolin• Component Btuh/ft2 Btuh % of load Walls 1.9 2479 13.8 w,r ?demi Cwin• Glazing 16.5 1975 11.0 Doors 12.9 542 3.0 °.-- Ceilings 3.2 4778 26.6 Floors 1.9 2888 16.1 Infiltration 0.3 506 2.8 Ducts 4329 24.1 Ventilation 0 0 '^ °^ Internal gains 460 2.6 Blower 0 0 Adjustments 0 Floora Total 17956 100.0 Latent Cooling Load= 2144 Btuh Overall U-value= 0.194 Btuh/ftZ-°F Data entries checked. Bold/Italic values have been manually overridden 2017-Ju1-16 13:24:00 I wrightsoft Right-Suite®Universal 2017 17.0.01 RSU20117 Page 1 -i 7,Cffr,, Projectl.rup Calc=MJB Front Door faces' N 4 wr'ightSOft$ Component Constructions Job: p Date: Jul 16,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE#13, OAKDALE, CT 06370 Design Conditions Location: Indoor: Heating Cooling New London(Bridgeport Dd), CT, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 64 10 Latitude: 41°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grub) 48.8 32.5 Dry bulb(°F) 8 85 Infiltration: Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fe B[UMN--'F ft'-'F/Btuh BIuhIIP Btuh Btuh/ft' Btuh Walls 12B-Osw:Frm wall,mtl ext,r-11 cay ins,1/2"gypsum board int fnsh, n 1338 0.097 11.0 6.21 8306 1.85 2479 2"x4"wood frm,16"o.c.stud Partitions (none) Windows 1D-c2ow:2 glazing,clr outr,air gas,wd frm mat,cll.innr,1/4"gap, n 120 0.570 0 36.5 4378 16.5 1975 1/8"thk;6.67 ft head ht Doors 11JO:Door,mtl fbrgl type n 42 0.600 6.3 38.4 1613 12.9 542 Ceilings 16A-19zd:Attic ceiling,membrane roof mat,r-19 cell ins,1/2" 1500 0.049 19.0 3.14 4704 3.18 4778 gypsum board int fnsh Floors 20P-Oc:Fir floor,frm fir,6"thkns,carpet flr fnsh,amb ovr 1500 0.385 0 24.6 36960 1.92 2888 I I E WCIghtsoft' Right-Suite®Universal 2017 17.0.01 RSU20117 2017-Jul-16 13:24:00Page 1 ACCA Projectl.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Date: Jul 16,2017 4 wrightsoft� p WHOLE HOUSE HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE#13, OAKDALE, CT 06370 Design Conditions Location: Indoor: Heating Cooling New London(Bridgeport Dd), CT, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 64 10 Latitude: 41°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 48.8 32.5 Dry bulb(°F) 6 85 Infiltration: ) Daily range(°F) - 20 ( M ) Method Simplified Wet bulb(°F) - 72 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 t Construction descriptions Or Area U-value Instil R Htg HTM Loss Clg HTM Gain ft. Btuh/ft.--°F ft.-'Fr8tuh Btuhfft. Btuh Btuh/ft. Btuh t. Walls 12B-Osw:Frm wall,mtl ext,r-11 cav ins,1/2"gypsum board int fish, n 1338 0.097 11.0 6.21 8306 1.85 2479 1 2"x4"wood frm,16"o.c.stud Partitions (none) Windows 1D-c2ow:2 glazing,clr outr,air gas,wd frm mat,clr innr,1/4"gap, n 120 0.570 0 36.5 4378 16.5 1975 1/8"thk;6.67 ft head ht Doors 11JO:Door,mtl fbrgl type n 42 0.600 6.3 38.4 1613 12.9 542 r. Ceilings 16A-19zd:Attic ceiling,membrane roof mat,r-19 ceil ins,1/2" 1500 0.049 19.0 3.14 4704 3.18 4778 1 gypsum board int fnsh Floors 20P-Oc:Fir floor,frm fir,6"thkns,carpet fir fnsh,amb ovr 1500 0.385 0 24.6 36960 1.92 2888 i e' ( 2017-Jul-1613:24:00 ' wrightsoft Right-Suite®Universal 2017 17.0.01 RSU20117 Page 2 AM. Projecti.rup Calc=MJ8 Front Door faces: N i &r Project Summary Job: wrightsoft Date: Jul 16,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Pro'ect Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE#13, OAKDALE, CT 06370 Notes: . .Desi• n Information Weather: New London(Bridgeport Dd), CT, US Winter Design Conditions Summer Design Conditions Outside db 6 °F Outside db 85 °F Inside db 70 °F Inside db 75 °F Design TD 64 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 32 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 62294 Btuh Structure 13627 Btuh Ducts 5842 Btuh Ducts 4329 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 68136 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 16161 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1416 Btuh Ducts 728 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft') 1500 1500 Equipment latent load 2144 Btuh Volume(ft') 12000 12000 Air changes/hour 0.45 0.23 Equipment total load 18305 Btuh Equiv.AVF (cfm) 90 46 Req. total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Low output baseboard 500 Btuh/ft Total cooling 0 Btuh Total low baseboard 136 ft Actual air flow 762 cfm High output baseboard 700 Btuh/ft Air flow factor 0.042 cfm/Btuh Total high baseboard 97 ft Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. vvrl htsoft 2017-Jul-1613.24.00 Right-SuRe�Universal 2017 17.0.01 RSU20117 Page 1 ACC . Projectl.rup Calc=MJ8 Front Door faces: N 4 AED Assessment Job: Date: Jul 16,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 Project Information For: DONNA YARBROUGH 15 MEETING HOUSE LANE#13, OAKDALE, CT 06370 Design Conditions Location: Indoor: Heating Cooling New London(Bridgeport Dd), CT, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 64 10 Latitude: 41°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 48.8 32.5 Dry bulb(°F) 6 85 Infiltration: Daily range(°F) - 20 ( M ) Wet bulb(°F) - 72 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 3,500- 3,000- 2,500- 2 ,500-3,000=2,500-2 . m 2,000— ° co .5. m ------------------\\ 1,500- 1,000- 500- 0 8 9 10 1i1 1'2 1�3 14 15 16 1I7 1I8 1I9 20� - Hour of Day /H°ury Average .-AED limit Maximum hourly glazing load exceeds average by 24.2%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh Bold/italic values have been manually overridden 2017-Jul-1613:24:00 ^ Wrightsoft-- Right-Suite®Universal 2017 17.0.01 RSU20117 Page 1 ACCK Projectt.rup Caic=MJB Front Door faces: N J -+-wrightsoft° Rig ht-J®Worksheet Doe: Jul 16,2017 Entire House By: HOP Energy/DDLC Energy 410 Bank St,New London,CT 06237 Phone:860-271-2020 License:303006 1 Room name Entire House WHOLE HOUSE 2 Exposed wall 160.0 ft 160.0 ft 3 Room height 8.0 ft d 8.0 ft heaUcool 4 Room dimensions 30.0 x 50.0 ft 5 Room area 1500.0 ft' 1500.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area number (Btuh/ft'-°F) (Btuh/ftl or perimeter (ft) (Btuh) or perimeter (ft) (Bttauh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W 12B-Osw 0.097 n 6.21 1.85 1500 1338 8306 2479 1500 1338 8306 2479 1D-c2ow 0.570 n 36.48 16.46 120 0 4378 1975 120 0 4378 1975 D 11J0 0.600 n 38.40 12.90 42 42 1613 542 42 42 1613 542 g C 16A-19zd 0.049 - 3.14 3.18 1500 1500 4704 4777 1500 1500 4704 4777 11 F 20P-Oc 0.385 - 24.64 1.92 1500 1500 36960 2887 1500 1500 36960 2887 6 c)AEC)excursion 0 0 Envelope loss/gain 55961 12661 55961 12661 12 a) Infiltration 6334 506 6334 506 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 62294 13627 62294 13627 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 62294 13627 62294 13627 15 Duct loads 9% 32% 5842 4329 9% 32% 5842 4329 Total room load 68136 17956 68136 17956 LowiHigh Baseboard/Cool Air 136 97 762 136 97 762 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ft 2017-Jul-16 13:24:00 wri htsO Right-Suite®Universal 2017 17.0.01 RSU20117 Page 1 ATA:1'.', Calc=MJ8 Front Door faces. N +, . .�m � � . .z»���< w��- . » . % . m. . ®«yam z« a£�,» : ������/ »v=�«: . � ^� ���� � »m.�®m©����:�����» �< � »;��<�����<�«< w : . . :��.. .. . . .�� � �\��\� > ) . . . w»« © . yy , d « \ . : ? «' \/ <. >f��wa���«w� < . � . .. . . . : a. . . .�. � �. . . . < Swazw=.«. : . . . . . .r'...'-,,.3,1i; «� ) / & � � f\ /^ . , : - . / f / ; ; } / \I ,.I / { / : /ti � ii /` «a } ! / , lil E ' \ ; � { l ! / ) } , \ � . . . � : ( . \ , , :a«a. a . ; y . . . . .> . a .: � . _ 1 1 1 v Z r� � n 3 < , s ,41UM • , l -••• , ' . ,...i, , ,_ I l ii ? , 1 1 3 11 V ,l !4 S h