Finish Basement 09/27/17 Permit Closed pursuant to Public Act 17-176—Required Inspections not
Job Description: completed—no approvals granted
Permit Number(s) B2005-0428 Permit Date: August 9 2005
Not Approved Approval
INSPECTION Date: Deficiencies Special Date
Conditions
• GFCI receptacles in bathroom don't function properly •
• Receptacle near boys bedroom has an open ground
Electrical 9/25/08 CC • You need to have an electrician repair the problems
and certify on their letter head that the wiring is up to
code
•
• Handrail needs to continue for the entire length of the •
stair
Stairs 9/25/08 CC • Stair tread depth and riser height is not to code but it
meets the exception
• Headroom height is only 72 inches
•
• No smoke detection or carbon monoxide protection •
in place
9/25/08 CC • Smoke detectors are required in all sleeping areas
Smoke Detection and outside of all sleeping areas
• Carbon monoxide detectors are required outside of
all sleeping areas
•
•
• I'll check egress window size(14%x 30%) •
Final inspection for • 14%x 30'/equals 3 square feet,5 square feet is
Certificate of 9/25/08 CC the minimum.The minimum height is 24 inches and
the minimum width is 20 inches
occupancy • If the sash are removable then your window will work
NOTICE: Before a certificate of occupancy can be issued, a C/O signoff sheet must be completed and
returned to the building department. Signoff sheets are available in the building department.